Integrating A Radius Accounting Server - Dell PowerConnect W-Airwave User Manual

W-airwave 7.2 user guide
Hide thumbs Also See for PowerConnect W-Airwave:
Table of Contents

Advertisement

Figure 25 AMP Setup > Authentication Page Illustration
2. Select No to disable or Yes to enable TACACS+ or RADIUS authentication. If you select Yes, several new
fields appear. Complete the fields described in
Table 29 AMP Setup > Authentication Fields and Default Values
Field
Primary Server
Hostname/IP Address
Primary Server Port
Primary Server Secret
Secondary Server
Hostname/IP Address
Secondary Server Port
Secondary Server
Secret
3. Select Save to retain these configurations, and continue with additional steps in the next procedure.

Integrating a RADIUS Accounting Server

NOTE: AWMS checks the local username and password before checking with the RADIUS server. If the user is found locally, the
local password and role apply. When using RADIUS, it's not necessary or recommended to define users on the AWMS server. The
only recommended user is the backup admin, in case the RADIUS server goes down.
Optionally, you can configure RADIUS server accounting on AMP Setup > RADIUS Accounting. This
capability is not required for basic AWMS operation, but can increase the user-friendliness of AWMS
administration in large networks.
Perform the following steps and configurations to enable AWMS to receive accounting records from a separate
RADIUS server.
illustrates the Add RADIUS Accounting Client page.
Dell PowerConnect W AirWave 7.2 | User Guide
Default
Description
N/A
Enter the IP address or the hostname of the primary RADIUS server.
1812
Enter the TCP port for the primary RADIUS server.
N/A
Specify and confirm the primary shared secret for the primary RADIUS server.
N/A
Enter the IP address or the hostname of the secondary RADIUS server.
1812
Enter the TCP port for the secondary RADIUS server.
N/A
Enter the shared secret for the secondary RADIUS server.
Figure 26
Figure 26
illustrates the display of RADIUS accounting clients already configured, and
Table
29.
illustrates the settings of this optional configuration interface.
Figure 27
Configuring AWMS | 55