10. Important note for working in practice

10.1. Simple stopping of the machine and the Emergency-Off switch

Press any key of the PC keyboard to stop the carriage movement and to switch off
the milling machine. The system will then wait for further commands.
This "Keyboard Stop" is helpful during the test phase and for disruptions of machining
(e.g. wrong infeed, wrong feed).

10.2. Safety stop, lock

Press the "Lock" (Sperren) switch of the CNC control to stop the carriage movement
and to switch off the spindle. The system will not accept any further commands until
the switch/pushbutton is returned to the "ON" (Ein) setting.

10.3. Direction of rotation switch

Your CNC machine no longer has a separate mains switch as it is
controlled directly via control electronics. However, during normal
work, make sure that the direction of rotation switch of the
machine (shown in the figure on the right) is not in the "0" setting,
but is set to the desired direction of rotation. Otherwise the
machine will not start.
That is why it must not be set to "0" during a machining procedure
either, since the spindle movement would be interrupted.

10.4. Room EMERGENCY Off

Room EMERGENCY Off: An EMERGENCY Off switch that disconnects the power
supply in the entire room must be installed in the room where the machines are
operated. This red/yellow coloured mushroom-shaped pushbutton must be easily
accessible and arranged far enough away from the possible hazardous area.