SmartWare Software Configuration Guide
Mode: Interface H.323
Step
1
node ( if- h323 )[ if-name ]#clip-clir-support Enables CLIP/CLIR support on the H.323
Example: Enable CLIP/CLIR support
The following example shows how to enable CLIP/CLIR support on the H.323 interface MyH323If.
node>enable
node#configure
node(cfg)#context cs
node(ctx-cs)[switch]#interface h323 MyH323If
node(if-h323)[MyH323If]#clip-clir-support

Enabling 'early-proceeding' on H.323 interfaces

The
early-proceeding
the gateway will immediately reply with an H.225 (H.323) call-proceeding message in response to a received
H.225 (H.323) setup message without waiting for a response from the destination.
Mode: interface h323 <if-h323>
Step
1
[ name ](if-h323)[ if-name ]#early-proceeding Enables the early-proceeding feature.
Example: Enable early call disconnect
The following example shows how to enable early call disconnect on an H.323 interface named MyH323If.
node>enable
node#configure
node(cfg)#context cs
node(ctx-cs)[switch]#interface h323 MyH323If
node(if-h323)[MyH323If]#early-disconnect

Enabling the early call disconnect (optional)

Early call disconnect suppresses busy tones (e.g. disturbing a telephone conference) and post-call announce-
ments by sending an H.323 Release message to the remote peer when the connected terminal hangs up (ISDN:
when Disconnect message is received; analog line: when busy tone is detected, loop current is interrupted, or
battery voltage is reversed).
Procedure: To enable early call disconnect
Mode: Interface H.323
Step
1
node (if-h323)[ if-name ]#early-disconnect
H.323 interface configuration task list
Command
command can enable the early-proceeding feature on H.323. If this feature is enabled,
Command
Command
32 • H.323 interface configuration
Purpose
interface
Purpose
Purpose
Enables early call disconnect (Default: dis-
abled)
374

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smartware release 3.21

Table of Contents