5.5.5 Configuring Sirens Functionality

The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 5.5.1.
Option
43:PANEL SIREN
Previously known as
"PIEZO SIREN"
44:SIREN TIME
Previously known as
"BELL TIME"
40
Configuration Instructions
disarms the system within the delay time, the alarm is aborted. You can activate the feature
and select the "Abort Time" interval.
Options: in 00 (default in USA)/15/30 (default)/45/60 seconds; in 2/3/4 minutes
Note:
To comply with UL or CP-01 requirements, the abort time must not exceed 45 sec. CP-01
features not to be enabled in UL Listed product.
The PowerMaster can be configured to provide a "Cancel Alarm" time window that starts
upon reporting an alarm to the Monitoring Station. If the user disarms the system within that
"cancel alarm" time, a "cancel alarm" message is sent to the Monitoring Station indicating that
the alarm was canceled by the user.
Options: not active (default in USA); in 1/5 (default)/15/60 minute(s) and in 4 hours.
Notes:
1. To comply with CP-01 requirements, "1 minute" option must not be used. CP-01 features
not to be enabled in UL Listed product.
.
The PowerMaster provides you with the following configurable options for resetting the alarm
condition and rearming the system:
By the user as usual - by user (default). By the engineer (installer) by entering and exiting the
"Installer Mode" or by accessing the system remotely via the telephone using the Installer
Code (by engineer). For accessing the system via the telephone, see the User's Guide,
Chapter 7 – "Remote Control by Telephone" and use the installer code instead of the user code.
Notes:
1. This feature is not applicable in the USA.
2. This feature is not to be not to be enabled in UL Listed product.
The PowerMaster is able to provide an "abort interval" that starts upon detection of a Fire event.
During this interval, the buzzer sounds a warning but the siren remains inactive and the alarm is
not reported. If the user disarms the system within the allowed abort interval, the alarm is
aborted.
The menu allows configuration of the length of time allowed by the system to abort a Fire alarm.
Options: 00 (default)/30/60/90 seconds
Configuration Instructions
Determine whether the control panel's built-in siren will sound alarms – "ON" (default) or
remain silent – "OFF".
Notes:
1. Panel siren must be enabled unless an external sounder is connected to the product.
For UL installations, when set to "OFF" the SR-720 PG2 and SR-730 PG2 sirens must be
2.
connected.
Define the period of time the sirens will sound upon alarm.
Options: 1/3/4 (default)/8/10/15/20 minute(s).
Notes:
1. To comply with EN requirements, the "Siren Time" must not exceed 15 minutes.
2. For Canada, the "Siren Time" must be set to 8 minutes
3. In UL installations, set siren time to 4 minutes min.
D-303222 PowerMaster-10/30 G2 Installer's Guide