4.5.28 Inst. DL Code

(Fig. 4.5, location 28). Here you determine the installer 4-
digit
password
for
PowerMaxComplete memory.
Attention! If "0000" is used, it will not enable connection of
the PowerMaxComplete to the PC for upload/download
purpose.

4.5.30 Zone Restore

(Fig. 4.5, location 30). Here you determine whether a zone
restore will be reported or not. Options: report restore and
don't report.

4.5.31 Upload Option

(Fig. 4.5, location 31). Here you determine whether the
PowerMaxComplete data can be uploaded into a computer
while the system is in disarm state or any time (in
HOME/AWAY arming & disarm state). The options are:
when system OFF and any time.

4.5.32 Dialing Method

(Fig. 4.5, location 32). Here you determine the dialing
method used by the automatic dialer built into the
PowerMaxComplete control panel.
The options are: Pulse and DTMF (tone).

4.5.33 Line Failure Report

(Fig. 5, loc. 33). Here you determine if the telephone line
disconnection will be reported or not and determine the
delay between detection of line disconnection and the
failure reporting. If the telephone line is disconnected, the
message "tel line fail" will be stored in the event log.

4.6 DEFINING GSM PARAMETERS

This mode is applicable only if your PowerMaxComplete is
connected to the internal / external GSM unit. By using this
mode, you can:
1. Define that the GSM unit is installed / not installed.
2. Define 4 cellular phone numbers to which events will be
reported via SMS text message.
3. Define which types of events will be reported to SMS
phone numbers.
4. Define whether the GSM unit will serve as:
GSM IS BACKUP – The system will try to report
events using the PSTN line, and if that fails, it will try
the GSM line (SMS messages are always sent
using the GSM line).
GSM IS PRIMARY –The system will try dialing
using GSM line first, and if that fails, it will try the
PSTN line (SMS messages are sent using GSM
anyway).
GSM ONLY –The system will report events by using
only the GSM line.
SMS ONLY –The system will not use GSM line for
anything else than for SMS messages.
5. Define whether GSM line failure will not be reported, or
will be reported after 2/5/15/30 minutes.
An illustrated process is shown in figure 4.6. In this
illustration, each selected option is displayed with a dark
box at the right side. To review the options, repeatedly
click
or
displayed, then click
22
downloading
data
into
button, until the desired option is
button.
The options are: don't report, immediately, 5 minutes,
30 minutes, 60 minutes or 180 minutes.

4.5.34 UL/DL Tel. Number

the
(Fig. 4.5, loc. 34). Here you enter the telephone number (up
to 16 digits) of the UL/DL server.
Note: Only for use with panels monitored by compatible
central stations. Leave empty if not being used.

4.5.35 System Inactivity Report

(Fig. 4.5, loc. 35). Here you determine whether the central
station will receive a message if the system is inactive (not
armed) during a defined period (days).
The options are: disable, rep. after 7d, rep. after 14d, rep.
after 30d, rep. after 90d.

4.5.38 Ambient Level

(Fig. 4.5 loc. 38). Applicable for USA only. In this section
you select the ambient noise level of the installation. If it is
relatively noisy environment, set it to High (default setting)
If it is very quiet environment, set to Low.

4.5.39 Report 24h Zones

Here you determine whether 24 hour (silent and audible)
zones will function as normal 24 hour zones or as panic
zones.
The options are: both original, audible as panic, silent
as panic, or both as panic.

4.6.1 GSM Module Installation

Here you define whether the GSM Module is installed or
not installed. Available options are: installed or not
installed.
4.6.2 1st, 2nd, 3rd & 4th SMS Number
Here you define the first, second, third and fourth SMS
phone number (including area code, 16 digits maximum) to
which pre-selected events types (see next paragraph) will
be reported.

4.6.3 Reporting to SMS Phone Number

Here you determine the types of events that will be
reported to the pre-selected SMS phone numbers.
Event messages are divided by type into three groups:
GROUP
EVENTS REPORTED
Alarms
Fire, Burglary, Panic, Tamper
Open/Close Arming AWAY, Arming HOME, Disarming
Alerts
No-activity, Emergency, Latchkey
The selectable options are detailed in the next table.
Option
All
all (-op/cl)
all (-alerts)
Alarms
Alerts
op/CL
Disable report
Note: "All" means that all 3 groups are reported and also
trouble messages - sensor / system low battery, sensor
inactivity, power failure, jamming, communication failure etc.
Description
All event types
All event types except open/close
All event types except alerts
Alarms only
Alerts only
Open/close only
No events reporting