Remote Control By Sms; Reporting By Sms - Visonic PowerMax User Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMax:
Table of Contents

Advertisement

Group 1 has the highest priority and group 3 has the
lowest priority.
When the called party answers a call initiated by the
PowerMax+, he will hear a verbal message
composed of the "house identity" and the type of
event that occurred. For example, once smoke is
detected in the Smith residence, the message will
be:
[The Smith Residence - Fire Alarm].
If a person under surveillance in the Watkins
residence has been inactive, the message will be:
[The Watkins Residence - No Activity].
The called party must acknowledge the message (as
explained later on), but if he does not respond, the
message will be transmitted repeatedly as many
times as possible within a 45-second time limit.
When the 45 seconds are up, the PowerMax+ will
disengage the line and call the next private
telephone number on its list.
The called party can acknowledge the message by
pressing a key on the telephone keypad, as follows.
Command
Acknowledge only: The PowerMax+
disengages the line and considers the
event duly reported.
Acknowledge
and
protected site is "bugged" for sound for
50 seconds. The called party may
prolong the listening session by pressing
[3]
again
before
disengages the line, or by pressing [1] to
speak.
Acknowledge and speak out: The
called party may speak for 50 seconds
to whoever is in the protected site. The
called party may prolong the "speak
out" session by pressing [1] again
before the PowerMax+ disengages the
line, or by pressing [3] to listen.
Acknowledge and 2-way conversation:
You and the called party can speak and
listen without any necessity to switch the
system from "listen-in" to "speak-out"
and vice versa for 50 sec. (extendable).
Acknowledge and request a status
report: The PowerMax+ will issue a
verbal report of system status. For
example:
[Disarm - ready to arm] or
[Disarm - back door open] or
[Disarm - alarm in memory].
DE5467U
Key
listen-in:
The
the
PowerMax+

Remote Control by SMS

PowerMax+ system with GSM unit can respond to
SMS commands from any cellular telephone, only if
the "REM ACCESS ON" command was pre-selected
by the system installer.
The various SMS commands are detailed in the
following table (the detailed SMS message sending
process is described in the cellular telephone user's
guide). In this table, "<code>" means 4-digit user
code and blank space simply means blank space.
Command
1
Arm AWAY
2
Arm AWAY instant
3
Arm AWAY
Latchkey
4
Arm AWAY
Latchkey instant
5
Arm HOME
2
6
Arm HOME instant "HOME INST <code>"
3
7
Disarm
8
Turn light xx on
(xx = 01 – 15)
9
Turn light xx off
(xx = 01 – 15)
1
10 Turn PGM on
11 Turn PGM off
12 Define custom
house identity (see
note)
6
13 Query system
status
Note: House ID includes up to 16 characters, for
example JOHN'S HOUSE.
9

Reporting by SMS

This option is applicable only if the GSM unit is
installed. The PowerMax+ system can send SMS
messages to a registered SMS telephones (up to 4).
(The SMS telephone registration is preselected by
the system installer).
The reported SMS messages are quite clear and
self- explanatory and therefore are not detailed in
this guide.
SPECIAL FUNCTIONS
SMS Command List
SMS Format
"AWAY <code>"
or "AW <code>"
"AWAY INST <code>"
or "AWI <code>"
"LATCHKEY <code>"
or "LK <code>"
"LATCHKEY INST
<code>"
or "LKI <code>"
"HOME <code>"
or "HM <code>"
or "HMI <code>"
"DISARM <code>" or "DA
<code>"
"LIGHT xx ON <code>"
or "LT xx ON <code>"
"LIGHT xx OFF <code>"
or "LT xx OFF <code>"
"PGM ON <code>"
"PGM OFF <code>"
"HOUSE NAME <code>
<house ID>"
or "HN <code> <house
ID>"
"STATUS <code>" or "ST
<code>"