Vinotemp WINE-MATE WM-1500HTD Installation, Use & Care Manual page 20

Hide thumbs Also See for WINE-MATE WM-1500HTD:
Table of Contents

Advertisement

d. Temperature controller fault
a. Evaporator air flow restriction
13.Evaporator
b. Condenser air flow restriction
freezing up
c. Not stopping due to air leak, high
d. Defective controller or probe
e. Low ambient temperature
f. Initially working then stopping,
g. Refrigerant low or leaking
h. Capillary tube blockage
a. Air leak in the wine cabinet
14.Water leak
b. High humidity
c. Evaporator air flow restriction or
d. Water passages restricted (water
e. Drip tray leak (No water overflow
a. Incorrect fuse or breaker
15.Circuit
b. Incorrect wirings
tripping
c. Failed components
a. Mounting area not firm
16.Noisy
b. Loose parts
operation
c. Compressor overloaded due to
d. Defective components
ambient
temperature,
temperature setting or pull-down
cooling
moisture in the system
(excessive condensate on the
front of the cooling unit)
low refrigerant
overflow)
but water leak)
high ambient temperatures or
airflow restriction
- 19 -
d. Change a new one
a. Check for fans and CFM
b. Check for fans and CFM
c. Check
for
seal,
low
ambient
temperature
temperature setting
d. Check for controller and probe
e. Change defrost cycle
f. Call service
g. Call service
h. Call service
a. Check for any air leak
b. Use drain line
c. Check supply air flow or air TD
crossing evaporator
d. Clean the drip tray
e. Seal the leak using silicone sealant
a. Check for proper fuse or breaker
b. Check for wirings and connections
c. Call service
a. Add support to improve installation
b. Check
fan
washers, tubing contact and loose
screws.
c. Check for airflow
d. Call service for checking internal
loose, inadequate lubrication and
incorrect wirings
door
opening,
and
blades,
bearings,

Advertisement

Table of Contents
loading

Table of Contents