Vinotemp WINE-MATE WM-1500HTD Installation, Use & Care Manual page 14

Hide thumbs Also See for WINE-MATE WM-1500HTD:
Table of Contents

Advertisement

4) Alarm Signals
The alarm codes are described as follows.
MESSAGE
P1
Temperature probe faulty
HA
High temperature alarm
LA
Low temperature alarm
CA
Probe alarms P1", start a few seconds after the fault in the related probe; they
automatically stop a few seconds after the probe restarts normal operation.
Check connections before replacing the probe. Temperature alarms "HA", "LA"
automatically stops as soon as the temperature returns to normal value. Alarm
"CA" (with i1F=PAL) recovers only by switching off and on the instrument.
2. Temperature Setting
• Set the temperature at 55
• On initial start-up, the time required to reach the desired temperature will
vary, depending on the quantity of bottles, temperature setting and
surrounding temperature.
• Allow 24 hours to stabilize the temperature for each new temperature setting
operation
3. How to see temperature set-point
1) Press and immediately release the SET key, the display will show the set-point
value.
2) Press again and immediately release the SET key or wait for 5 seconds to
display the probe value.
4. How to change the set-point
1) Press the SET key for more than 3 seconds until the "°C" or "°F" LED starts
blinking and the set-point will be displayed.
2) To change the set value, press the up/down keys
3) To store the new set-point value, press the SET key again or wait 10 sec.
NOTE: The unit turns on at set-point Set plus regulation differential Hy after anti-
short cycle AC has elapsed; the unit turns off at set-point Set.
CAUSE
Probe temperature ALU higher than the
setting temperature; Outputs unchanged
setting temperature; Outputs unchanged
External alarm
°
F
for the optimum aging of wine
- 13 -
FUNCTION
Compressor switching to Con and CoF
Probe temperature ALL lower than the
All outputs off
/
within 10 sec.