Tone frequencies
Tone cadences
Environmental requirements
Doorstrike relay contact
Door Phone Size
Color of System
Broadband Module Info
Call recalling
1s on 400 ms off,
400 ms on 1.2 s off
440 Hz ±5 Hz, unless stated otherwise
Dial Tone
Continuous tone of 440 Hz ±5%
and 350 Hz ±5% combined
Special dial tone
800 ms on 800 ms off of 440 Hz ±5%
and 350 Hz ±5% combined
Ringback tone
1 sec on 2 sec off
Busy tone
500 ms on 500 ms off
Congestion tone
200 ms on 200 ms off
Hold tone 200 ms on 200 ms off,
200 ms on 3.4 s off
Conference tone
One burst of 400 ms
NU tone
Continuous tone
Call waiting tone
100 ms on 4.9 s off
Normal working temperature
Storage temperature
Working humidity (non-condensing)
Storage humidity
Max rating
24 Volts DC
2 Amps
Height
8 inches (203 mm)
Width
2.9 inches (73 mm)
Depth
1.5 inches (38 mm)
Charcoal ref: Pantone 432C
LAN
4 x 10/100 Base-Tx Extension
DSL
On Board ADSL Modem
ISDN
Access to B-channels on PABX PPP
Protocols
IP V4
Authentication
PAP/CHAP
DHCP
DHCP server
Routing
Static routing
Firewall
NAT, Packet filtering, stateful inspection.
VoIP
12 VoIP channels
SIP Protocol
Management
Local management via MPS or LAN Browser
Remote management via MPS over CO Line
127
Mitel 3000
Installation & Maintenance Manual
°
°
0
C to 40
C
°
°
-40
C to +85
C
5% to 95%
°
5% to 95% @60