46-19
Purpose
Adjustment
Function
Used to change the image quality in the exposure
(Purpose)
mode.
Item
Picture quality
Operation/procedure
Select the mode with the 10-key and press the [OK] key.
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
Pressing the [BACK] key returns to the mode selection.
Auto exposure mode
• When SIM 26-6 (Destination setup) is changed from EX to Japan,
the setup value becomes 1 (Default: Japan). If, on the contrary, it is
changed from Japan to EX, the set value becomes 2 (Default: EX)
• If the auto exposure mode setup value is changed, the setup value
of SIM 46-30 (AE limit setup) is reset to the default value.
(Initial screen)
(Input screen)
Sim46-19 AE MODE
Sim46-19 AE MODE
1:AE MODE
1
1:AE MODE
2:AE STOP(COPY)
0
(1:EXPOSURE
3:AE STOP(FAX)
0
2:TONER)
1/2
1
[ 1- 2]
Display items
Auto exposure mode
1:AE MODE
(1: Priority on Image quality,
(1:EXPOSURE
2: Priority on toner consumption)
2:TONER)
Auto exposure STOP mode
2:AE STOP(COPY)
(COPY)
(0:FIXED
(0: Fixed, 1: Real-time)
1:REAL TIME)
Auto exposure STOP mode (FAX)
3:AE STOP(FAX)
(0: Fixed, 1: Real-time)
(0:FIXED
1:REAL TIME)
Auto exposure STOP mode
4:AE STOP(SCAN)
(SCANNER)
(0:FIXED
(0: Fixed, 1: Real-time)
1:REAL TIME)
1200dpi photo mode
5:1200dpi PHOTO
(Countermeasures for claims on
(1:SOFT
dither)
2:HARD)
(1: Soft mode, 2: Hard mode)
46-20
Purpose
Adjustment
Function
Used to correct SPF exposure.
(Purpose)
Item
Picture quality
Operation/procedure
Select the mode with the 10-key and press the [OK] key.
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
Pressing the [BACK] key returns to the mode selection.
(Initial screen)
(Input screen)
Sim46-20 SPF EXP.
Sim46-20 SPF EXP.
1:SPF EXPOSURE
53
1:SPF EXPOSURE
2:RSPF EXPOSURE 53
1
[ 1- 99]
Display items
Content
SPF
1:SPF EXPOSURE
RSPF
2:RSPF EXPOSURE
1
1
Content
Default
2
0
0
0
Disabled
53
50
Setting range
Default
1-99
53
AR-5127 SIMULATION 8 - 29
46-30
Purpose
Setting
Function
Used to set the AE limit.
(Purpose)
Operation/procedure
Select the mode with the 10-key and press the [OK] key.
Enter the adjustment value with the 10-key and press the [OK] key, and
the entered value is registered.
Pressing the [BACK] key returns to the mode selection.
If SIM 26-6 (Destination setup) and SIM46-19 (Auto exposure mode)
are changed, this setup is also changed to the default value accord-
ingly.
(Initial screen)
(Input screen)
Sim46-30 AE LIMITTE
Sim46-30 AE LIMITTE
1:AE
0
1:AE
2:AE(TS)
0
1
[ 0- 31]
Display items
Setting range
0-31
1:AE
2:AE(TS)
48
48-1
Purpose
Adjustment
Function
Used to adjust the copy mode magnification ratio (main
(Purpose)
scanning direction, sub scanning direction).
Section
Image processing
Item
Picture quality
Operation/procedure
Select the mode with the arrow keys, enter the adjustment value with
the 10-key, and press the [OK] key.
When the [START] key is pressed, a print is made and the display
returns to the mode selection menu.
(Initial screen)
(Input screen)
Sim48-1 COPY MAG.
1:F-R(AUTO)
50
2:F-R
50
3:SCAN
50
1/2
50
Display items
Content
Main scanning magnification
1:F-R(AUTO)
ratio adjustment (auto)
Main scanning magnification
2:F-R
ratio adjustment
Sub scanning magnification
3:SCAN
ratio adjustment
SPF surface sub scan
4:SPF(SIDE1)
magnification ratio
SPF back surface sub scan
5:SPF(SIDE2)
magnification ratio
DUPLEX sub scanning
6:DUPLEX
magnification ratio adjustment
Setup of various copy conditions: Similar to the normal copy mode.
Use of [SPECIAL FUNCTION] key, [JOB STATUS] key, and [INTER-
RUPT] key is inhibited.
0
0
Default
0
(Executing screen)
Setting
Default
range
1-99
50
60
50