When selected without setup, the selected value is registered and
highlighted. When selected with previous setup, the previous setup is
canceled and it is displayed normally.
This setting is canceled by power OFF.
Note: In SIM 7-1, pressing [CA] key terminates the simulation and the
machine enters the aging mode without resetting. Therefore, to
perform "4. Intermittent setup," the intermittent cycle must be set
with SIM 7-6 in advance.
Reset is not performed when the machine enters the aging
mode.
7-6
Purpose
Setting/Operation test/check
Function
Used to set the cycle of intermittent aging.
(Purpose)
Item
Operation
Operation/procedure
Enter the interval aging cycle time (sec) with the 10-key pad. Refer to
7-1.
Sim7-6 INTERVAL SET
AGING INTERVAL
3
[ 1-255]
3
Setting range
1-255
Default
3
7-8
Purpose
Setting/Operation test/check
Function
Used to set the display of the warm-up time.
(Purpose)
Item
Operation
Operation/procedure
Warm-up starts by the cover open/close.
(Can be performed repeatedly by open/close of the cover.)
The warm-up time is counted up and displayed in the unit of sec.
(Initial screen)
(Executing screen)
Sim7-8 WARM UP TIME
Sim7-8 WARM UP TIME
PLEASE COVER
WARMING UP,
OPEN AND CLOSE
PLEASE WAIT.
If the [CA] key is pressed at this time, count-up is interrupted to termi-
nate the simulation. (However, warm-up is continued.)
After completion of warming up, "WARM UP COMPLETED" is dis-
played and the control returns to the initial screen.
8
8-1
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of the
(Purpose)
developing bias voltage in each copy mode and the
control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
(Initial screen after completion)
Sim7-8 WARM UP TIME
PLEASE COVER
OPEN AND CLOSE
WARM UP COMPLETED.
1
10
AR-5127 SIMULATION 8 - 9
(Initial screen)
(Input/Selection screen) (Executing screen)
Sim8-1 DV BIAS COPY
Sim8-1 DV BIAS COPY
1:AE
400
5:SUPER PHOTO
2:TEXT
450
3:TEXT/PHOTO
450
1/2
EXEC [200-550]
Display items
Content
AE ( )
1:AE
Character
2:TEXT
Character/Photo
3:TEXT/PHOTO
Photo
4:PHOTO
Super photo
5:SUPER PHOTO *
Toner save
6:TONER SAVE
( ) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
* SUPER PHOTO (5:) cannot be executed.
When [OK] or [START] key is pressed, a caution buzzer sounds.
(Only the adjustment value can be entered.)
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [OK] key.
8-2
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of the main
(Purpose)
charger grid voltage (high mode) in each copy mode
and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.
(Initial screen)
(Input/Selection screen) (Executing screen)
Sim8-2 MHV(H) COPY
Sim8-2 MHV(H) COPY
1:AE
3
5:SUPER PHOTO
2:TEXT
5
3:TEXT/PHOTO
5
1/2
EXEC [ 1- 8]
Display items
Content
AE ( )
1:AE
Character
2:TEXT
Character/Photo
3:TEXT/PHOTO
Photo
4:PHOTO
Super photo
5:SUPER PHOTO *
Toner save
6:TONER SAVE
( ) Linked with the destinations of SIM 26-6.
Linked with the auto exposure mode of SIM 46-19-1.
* SUPER PHOTO (5:) cannot be executed.
When [OK] or [START] key is pressed, a caution buzzer sounds.
(Only the adjustment value can be entered.)
Sim8-1 DV BIAS COPY
400
5:SUPER PHOTO
400
400
EXEC
[200-550]
400
Installation
Default
range
200-550
400 (–400V)
450 (–450V)
450 (–450V)
450 (–450V)
Disabled
376 (–376V)
Sim8-2 MHV(H) COPY
3
5:SUPER PHOTO
3
3
EXEC
[ 1- 8]
3
Setting
Default
range
1-8
3 (–530V)
5 (–580V)
5 (–580V)
5 (–580V)
Disabled
2 (–505V)