24-9
Purpose
Data clear
Function
Used to clear the printer print counter. (The counter is
(Purpose)
cleared after completion of maintenance.)
Section
Printer
Item
Counter
Operation/procedure
Clear the counters individually.
(Initial screen)
(Check screen)
Sim24-9 COUNTER CLR
Sim24-9 COUNTER CLR
1:PRINTER 4:OTHERS
1:PRINTER 4:OTHERS
2:IMC
2:IMC
3:DUPLEX
3:DUPLEX
2
ARE YOU SURE?
Printer counter
1:PRINTER
IMC counter
2:IMC
DUPLEX counter
3:DUPLEX
The other counters
4:OTHERS
24-10
Purpose
Adjustment/Setting/Check
Function
FAX related counter clear
(Purpose)
Operation/procedure
The current counter value (number of send/receive pages) of the FAX
send/receive counter and the accumulated reception time and the print
counter are cleared to 0.
Note: Executable only when the FAX is installed.
24-15
Purpose
Data clear
Function
Used to clear the scanner mode counter.
(Purpose)
Item
Counter
Operation/procedure
Press the [OK] key.
The scanner mode counter and the number of send of the scanner are
cleared.
(Initial screen)
(Process check screen)
Sim24-15 COUNTERCLR
Sim24-15 COUNTERCLR
SCANNER MODE
SCANNER MODE
COUNTER CLEAR
COUNTER CLEAR
PRESS OK KEY
ARE YOU SURE?
* Execution is inhibited until GDI or PCL board is securely installed.
(Because the board is detected by the software.)
25
25-1
Purpose
Operation test/check
Function
Used to check the operation of the main drive
(Purpose)
(excluding the scanner section) and to check the
operation of the toner concentration sensor. (The toner
concentration sensor output can be monitored.)
Section
DRIVE
Item
Operation
Printer
2
AR-5127 SIMULATION 8 - 18
Operation/procedure
The operation of the drive system is checked.
Toner density control sensor value is displayed.
Select the mode with the 10-key and press the [OK] key, and the main
motor will rotate and the toner concentration control sensor value will
be displayed.
After execution, interruption cannot be made for about 7 sec. ([CA] key,
[INTERRUPT] key, and [BACK] key are invalid.)
(Initial screen)
(Executing screen)
Sim25-1 MAIN MOTOR
Sim25-1 MAIN MOTOR
1:600dpi
1:600dpi
2:1200dpi
2:1200dpi
EXEC
2
* Even though in toner END, if no other error (including cover open)
occurs after supplying power, execution of this command is allowed.
25-2
Purpose
Setting
Function
Used to make the initial setting of toner concentration
(Purpose)
when replacing developer.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Operation/procedure
1) Open the cover.
2) Power ON. (The mechanism cannot be initialized because the
cover is open.)
3) Install the developing unit with new developer in it.
4) Enter SIM 25-2.
5) Close the cover immediately before starting the operation.
6) Press the [OK] key to start.
Sampling is made 54 times every 600ms, and the average of the last
three times in the last 1.8sec of 3min is stored.
When "EE-EU" or "EE-EL" after completion, an error display is shown.
EU error occurs when the finally calculated toner concentration refer-
ence value is 179 or greater.
EL error occurs when the finally calculated toner concentration refer-
ence value is 77 or smaller.
(Initial screen)
(Executing screen)
Sim25-2 AUTO DV ADJ
Sim25-2 AUTO DV ADJ
AUTO DEVE ADJUST
AUTO DEVE ADJUST
[128]
PRESS OK KEY
EXEC
Note: After completion of execution, be sure to press the [CA] key to
cancel the simulation.
[CRUM-related error cancel procedure]
• When "CRUM DEVICE ERROR" is displayed:
Error content:
Occurs in case of a communication error
between the machine and CRUM.
Cancel procedure: Reset with [CA] key and cancel with SIM 16.
• "CRUM DATA ERROR"
Error content:
CRUM identification error, CRUM model error,
CRUM type error, CRUM destination error
Cancel procedure: Install the CRUM which is satisfactory with the
machine setup, reset with the [CA] key, and
execute SIM 25-2 again.
• "DEVE UNIT NONE"
Error content:
Occurs when the developing unit is not installed
in an AR model.
[128]
EXEC
2