Sharp AR-5127 Service Manual page 39

Digital laser copier/printer
Hide thumbs Also See for AR-5127:
Table of Contents

Advertisement

Display items
Content
Density 1 (600dpi)
1:DENS1(600)
Density 2 (600dpi)
2:DENS2(600)
Density 3 (600dpi)
3:DENS3(600)
Density 4 (600dpi)
4:DENS4(600)
Density 5 (600dpi)
5:DENS5(600)
Toner save (600dpi)
6:TS(600)
Density 1 (1200dpi)
7:DENS1(1200)
Density 2 (1200dpi)
8:DENS2(1200)
Density 3 (1200dpi)
9:DENS3(1200)
Density 4 (1200dpi)
10:DENS4(1200)
Density 5 (1200dpi)
11:DENS5(1200)
NO.
Set value
Grid High
1
480
–480V
2
505
–505V
3
530
–530V
4
555
–555V
5
580
–580V
6
605
–605V
7
630
–630V
8
655
–655V
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
8-12
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of the main
(Purpose)
charger grid voltage (low mode) in each printer mode
and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Operation/procedure
After selecting the mode, enter the adjustment value and press the
[OK] key, and output will be made for 30sec.
The input value is in the increment of –25V.
(Initial screen)
(Input/Selection screen) (Executing screen)
Sim8-12 MHV(L) PRT
Sim8-12 MHV(L) PRT
1:DENS1(600)
3
5:DENS5(600)
2:DENS2(600)
5
3:DENS3(600)
5
1/4
EXEC [ 1- 8]
Display items
Content
Density 1 (600dpi)
1:DENS1(600)
Density 2 (600dpi)
2:DENS2(600)
Density 3 (600dpi)
3:DENS3(600)
Density 4 (600dpi)
4:DENS4(600)
Density 5 (600dpi)
5:DENS5(600)
Toner save (600dpi)
6:TS(600)
Density 1 (1200dpi)
7:DENS1(1200)
Density 2 (1200dpi)
8:DENS2(1200)
Density 3 (1200dpi)
9:DENS3(1200)
Density 4 (1200dpi)
10:DENS4(1200)
Density 5 (1200dpi)
11:DENS5(1200)
Installation
Default
range
1-8
5 (–580V)
5 (–580V)
5 (–580V)
5 (–580V)
7 (–630V)
3 (–530V)
Disabled
Disabled
Disabled
Disabled
Disabled
Grid Low
–350V
–375V
–400V
–425V
–450V
–475V
–500V
–525V
Sim8-12 MHV(L) PRT
7
5:DENS5(600)
7
EXEC
[ 1- 8]
Installation
Default
range
1-8
5 (–450V)
5 (–450V)
5 (–450V)
5 (–450V)
7 (–500V)
3 (–400V)
Disabled
Disabled
Disabled
Disabled
Disabled
AR-5127 SIMULATION 8 - 11
NO.
Set value
1
480
2
505
3
530
4
555
5
580
6
605
7
630
8
655
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
8-13
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of the
(Purpose)
developing bias voltage in FAX mode and the control
circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Developer/Toner hopper
Operation/procedure
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec.
(Initial screen)
Sim8-13 DV BIAS FAX
FAX
426
EXEC [200-550]
4260
Setting range 200-550
Default
426
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [OK] key.
8-14
7
Purpose
Adjustment/Operation test/check
Function
Used to check and adjust the operation of the main
7
(Purpose)
charger grid voltage (high mode) in FAX mode and the
control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Photo conductor
Operation/procedure
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec.
(Initial screen)
Sim8-14 MHV(H) FAX
FAX
5
EXEC [ 1- 8]
5
Setting range
1-8
Default
5
Grid High
Grid Low
–480V
–350V
–505V
–375V
–530V
–400V
–555V
–425V
–580V
–450V
–605V
–475V
–630V
–500V
–655V
–525V
(Executing screen)
Sim8-13 DV BIAS FAX
FAX
426
EXEC
[200-550]
426
(Executing screen)
Sim8-14 MHV(H) FAX
FAX
5
EXEC
[ 1- 8]
5