4. USING THE COUNTER

(1) Setting procedure of the counter

A
B
Counter setting screen
(Screen A)
Sewing counter setting
screen (Screen B)
1 Display the counter setting screen.
Press MODE CHANGEOVER key
COUNTER SETTING button
Press this button and "COUNTER SETTING screen (screen A)" is
displayed.
2 Select the kind of counter.
There are three kinds of counters with this sewing machine,
sewing counter, number of pcs. counter and bobbin thread
remaining amount adjustment counter.
Press sewing counter button
(screen A)", and "sewing counter setting screen (screen B)" is
displayed. Then the kind of counter can be set.
UP counter
Every time one sewing is performed, the existing value is counter
up. When the existing value is equal to the set value, the count-
up screen is displayed.
DOWN counter
Every time one sewing is performed, the existing value is counted
down. When the existing value is reached to "0", the count-up
screen is displayed.
Counter unused
Sewing counter is set to the prohibition.
− 34 −