Modes of Operation

The following are application examples of Operation Modes for the IE-MiniFiberLinX-
II. There are six modes of operation that can be configured through the Serial/Telnet
session. All modes of operation block management traffic from the user network on
the Data port.
Mode One - Default
The default mode is provided to pass only untagged traffic.
Default Plus
The Default Mode Plus allows tagged and untagged traffic to pass between the data
and optics ports.
Mode Two - Transparency with Untagged Management
This mode is designed to pass all tagged and extra-tagged customer traffic unchanged
and must be managed using untagged traffic only. It does not add or remove tags.