FiberAlert
FiberAlert minimizes the problems associated with the loss of one strand of fiber.
Normally when a single strand of fiber is lost, the transmitting side of the connection
is unaware that there is a fault. FiberAlert returns faults back on the fiber they came
in on.
Using LinkLoss and FiberAlert
In a typical central site to remote site media conversion, it is recommended the
LinkLoss and FiberAlert features are enabled as indicated in the following:
Feature
FiberAlert
Remote Side Only
TX LinkLoss
Remote Side (or both)
FX LinkLoss
Host Side (or both)
Do not enable FiberAlert on both modules when using them in pairs. This will cause them to
lock up when a fault occurs on the fiber. Only enable FiberAlert on the remote module.
Link Fault Pass Through (LFPT)
Link Fault Pass-Through (LFPT) is a troubleshooting feature that combines TX and FX
LinkLoss from both the local and remote IE-MiniFiberLinX-II. LFPT is enabled by
turning on both FX and TX LinkLoss on both modules. This feature allows either end
of the conversion to detect a link fault occurring at the other end of the media
conversion chain.
Regardless if there is a break in segment 1, 2 or 3, the link will drop on the switches
at both ends. The link fault is passed through the media conversion and is observed at
each end. It acts just like it would if the devices were directly connected.
FiberAlert and LinkLoss
Enabled
Fault Location
Fiber
Twisted Pair
Fiber
WARNING
7
Port Affected
Fiber
Fiber
Twisted Pair

Advertisement