TCP Error Messages
Effect. The receive operation fails. The session is closed and the TERM object is
reinitialized for a new session.
Recovery. Informational message only; no corrective action is needed.
3161: ZPWY-ERR-TCP-MSGIO
An I/O error occurred during a SEND MESSAGE operation or during a REPLY TO
UNSOLICITED MESSAGE operation.
This error does not appear in the RETCODE token or in an error list; it appears only in
response to a STATUS TCP or STATUS TERM command.
Effect. The operation fails.
Recovery. For information regarding the specified file-system error, see the Guardian
Procedure Errors and Messages Manual.
3162: ZPWY-ERR-TCP-RCVDMSGTOOSMALL
The message received from a RECEIVE UNSOLICITED MESSAGE operation or as a
reply to a SEND MESSAGE operation was smaller than allowed.
This error does not appear in the RETCODE token or in an error list; it appears only in
response to a STATUS TCP or STATUS TERM command.
Effect. The operation fails.
Recovery. Isolate and correct the problem within the SCREEN COBOL program. For
instructions on how to locate the problem within the program, see
Information for Terminal Errors
3163: ZPWY-ERR-TCP-RCVDMSGTOOBIG
The message received from a RECEIVE UNSOLICITED MESSAGE operation, a
TRANSFORM operation, or a SEND MESSAGE operation was larger than allowed; a
data overflow occurred.
The number of bytes the TCP receives during data overflow may be less than the
number of bytes the IDS or UMP process sends.
This error does not appear in the RETCODE token or in an error list; it appears only in
response to a STATUS TCP or STATUS TERM command.
Effect. The operation fails.
Recovery. Isolate and correct the problem within the SCREEN COBOL program. For
instructions on how to locate the problem within the program, see
Information for Terminal Errors
NonStop Pathway/iTS Management Programming Manual—426749-002
on page 12-3.
on page 12-3.
12 -32
Error-Message Range 3000 Through 3999
Additional
Additional
Need help?