PROG Commands
Command Syntax
For tokens that may be present in the command and response buffers but are not
listed, see
Unlisted Tokens
Section 4 through Section 6.
Command
ZPWY-CMD-ADD
Object Type
ZPWY-OBJ-PROG
Tokens in Command Buffer
ZPWY-MAP-SEL-PROG
ZPWY-MAP-DEF-PROG
Tokens in Response Buffer
ZPWY-MAP-SEL-PROG
ZSPI-TKN-RETCODE
Tokens in Response Buffer
ZSPI-TKN-RETCODE
For ADD PROG, common error values for ZSPI-TKN-RETCODE are:
Error
Number
1012
1108
For descriptions of error-token values and their associated error lists, see
Section 11, TCP Event Messages
Considerations
Before adding a PROG object description to the PATHMON configuration file, you
must assign values to all of the required fields listed in this command.
Each PROG name (the value in ZPWY-DDL-SEL-PROG) must be unique in the
Pathway subsystem.
NonStop Pathway/iTS Management Programming Manual—426749-002
on page 3-36. For descriptions of tokens and fields, see
Error Token
ZPWY-ERR-PM-DUPNAME
ZPWY-ERR-PM-
TOOMANYPROG
token-type ZPWY-DDL-SEL-PROG.
token-type ZPWY-DDL-DEF-PROG.
token-type ZPWY-DDL-SEL-PROG.
token-type ZSPI-TYP-INT.
Description
The PATHMON process encountered a
duplicate PROG object name.
The value specified for ZMAXPROGS
was reached.
and
Section 12, TCP Error
9 -2
ADD PROG
!r
!r
Messages.