Zpwy-Map-Def-Prog - HP NonStop Pathway/iTS Programming Manual

Management programming manual
Table of Contents

Advertisement

ZPWY-MAP- Definitions

ZPWY-MAP-DEF-PROG

ZPWY-MAP-DEF-PROG identifies an extensible structured token that defines the
attributes for a Pathway subsystem PROG object (equivalent to the PROGRAM object
in PATHCOM).
def ZPWY-DDL-DEF-PROG.
02 ZERRORABORT
02 ZOWNER.
03 ZSYSTEMNUMBER
03 ZGROUPNUMBER
03 ZUSERNUMBER
02 ZPRINTERINFO.
03 ZISATTACHED
03 ZPRINTERFILE
02 ZSECURITY
02 ZTCP
!r
02 FILLER
02 ZTMF
end.
ZERRORABORT
specifies whether the TCP aborts or suspends the terminal if a RUN PROGRAM
error occurs in the SCREEN COBOL program. The following values are valid:
ZPWY-VAL-OFF
ZPWY-VAL-ON
If you do not assign a value to this field, the default is ZPWY-VAL-ON.
ZOWNER
specifies the user ID authorized to start a PROG object. The user ID must be
known to the system in which the program is running. The value of the ZOWNER
field works in conjunction with the value you set for the ZSECURITY field.
For more information, see the
If you do not assign a value to this field, the default is the owner ID of the user who
adds the program.
ZPRINTERINFO
specifies the printer to be used for the SCREEN COBOL PRINT SCREEN verb.
The fields are described under ZPWY-DDL-PRINTER-INFO in this section.
NonStop Pathway/iTS Management Programming Manual—426749-002
token-type ZPWY-DDL-ON-OFF.
token-type ZSPI-DDL-INT.
token-type ZSPI-DDL-INT.
token-type ZSPI-DDL-INT.
token-type ZPWY-DDL-YES-NO.
token-type ZSPI-DDL-FNAME32.
token-type ZPWY-DDL-SECURITY-VALUE.
token-type ZPWY-DDL-OBJECT-NAME .
token-type ZPWY-DDL-FILLER.
token-type ZPWY-DDL-ON-OFF.
Directs the TCP to suspend a terminal if a program run error
occurs.
Directs the TCP to abort a terminal if a program run error
occurs.
ZPWY-DDL-OWNER-ID
6 -6
ZPWY-MAP-DEF-PROG
on page 5-14.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents