Standard Oven

Lighting
1 Remove oven buttons.
2. Depress and hold the reset button (Red) located at the
lower front of the oven (beneath the oven door) while
lighting the oven pilot. Continue to depress the rest
button for 60 seconds. Release the button, if the pilot
does not stay lit, repeat this procedure after 5 minutes
LIGHT BURNER THRU INSIDE
OF OVEN W/MATCH
Shut down
1. Turn all valves and thermostats to the off position.
2. If a range is to be shut down for an extended period of
time, close the in line gas valve.
Relighting
1 Shut all gas valves off.
2. Wait 5 minutes.
Part # GCTRM Rev 3 (12/10/09)
3. Repeat lighting instructions in section "A" above.
G, U, X Restaurant Ranges (Sit Control)
Lighting
1. Push in the SIT control knob.
2. When the pilot is lit, continue to hold the valve knob fully
3. When the pilot has been established, turn the knob
RESET BUTTON
ON SAFETY
4. To keep the main burner flame off and but the pilot flame
While holding the valve knob fully in, press the ignitor
button and light the oven pilot.
in for 10 seconds, then release it. If the pilot goes out, wait
for five (5), minutes, then repeat step 1.
counter-clockwise, and align the desired oven
temperature to the 12:00 position.
lit ,turn the control knob clockwise to the stop position.
This knob is configured to leave the pilot on continuously.