1. Turn all griddle temperature control dials to 350°F
(177°C). In order to allow the temperature to stabilize,
the controls must be allowed to cycle three times before
taking a test reading.
2. Check the temperature reading when the control cuts
down to by-pass by placing the sensor firmly on the
griddle surfaces directly above the sensing bulb of
the control. Reading of the test instrument should be
between 335°F (168°C) and 365°F (185°C).
3. If the dial setting does not agree with the test instrument
reading within the above limits, re-calibrate as follows:

Electric Thermostat

Thermostat Operation
It is normal for a hydraulic thermostat to cycle with a
temperature differential of 45° to 50°. If the thermostat is
cycling beyond the 15° tolerances above or below the set
point and the appliance is under warranty, re-calibrate the
thermostat or if not under warranty, consult the owner for
proper action. If the thermostat is out of calibration more
than 50°, it will not likely hold an attempt of re-calibration.
We suggest that the thermostat be replaced.
Page 46
Dial Shaft
Calibration Screw Head
4. Remove the dial making sure the setting is not disturbed.
5. Each division mark on the calibration plate equals 15°F.
With a screw driver, turn the calibration screw clock-wise
(toward LOW) to reduce the temperature, or counter-
clockwise (toward HIGH) to increase the temperature.
Example – The dial setting is at the 350°F mark. The test
instrument is reading 380°F. Turn the calibration screw
clockwise (toward LOW) two divisions.
6. Replace the dial, turning the dial to the "OFF" position.
7. Repeat steps 1 through 3 to make sure the correct
adjustment has been made.
Calibration
Screw Head
1/4" Turn
Thermostat calibration
Oven thermostat
1 Place the thermocouple of the test instrument in the
center of the oven.
2. Turn the oven temperature control dial to 400°F. In order
to allow the oven temperature to stabilize, the oven
control must be allowed to cycle twice before taking a
test reading.
3 Check the temperature reading just when the control
cycles "OFF" as indicated by the cycling pilot lamp. If the
temperature dose not read within 15° of the dial setting,
re-calibrate as follows:
Increase
Decrease
Part # GCTRM Rev 3 (12/10/09)