D Checking The Repeater Input Signal; Off Band Indication - Icom IC-E90 Instruction Manual

Multiband fm transceiver
Hide thumbs Also See for IC-E90:
Table of Contents

Advertisement

D Checking the repeater input signal

The transceiver can check whether the other station's trans-
mit signal can be received directly or not.
➥ Push and hold [SQL] to check whether the other station's
transmit signal can be directly received or not.
• When the other station's signal can be directly received, move to
a non-repeater frequency with simplex. (duplex OFF)
[SQL]
Indication while receiving
FM
DUP
T
P
SKIP
SQL
Receives –5 MHz shift frequency
FM
DUP
T
P
SKIP
D Off band indication
If the transmit frequency is out of the amateur band, the off
band indication "OFF" appears on the display when [PTT] is
pushed. Check the offset frequency or duplex direction in this
case. (p. 31)
FM
DUP T
➲ CONVENIENT
Tone scan function: When you don't know the subaudible
tone used for a repeater, the tone scan is convenient for de-
tecting the tone frequency.
➥ Push [7 T.SCAN] for 1 sec. to activate. See p. 73 for more
information.