B – Command Line Interface

Test Command

Test Command
Tests ports using internal (SerDes level), external (SFP), and online loopback
tests. Internal and external tests require that the port be placed in diagnostic
mode. Refer to the
the port administrative state. While the test is running, the remaining ports on the
switch remain fully operational.
Authority
Admin
Syntax
test
port [port_number] [test_type]
cancel
status
Keywords
port [port_number] [test_type]
Tests the port given by [port_number] using the test given by [test_type]. If you
omit [test_type], Internal is used. [test_type] can have the following values:
internal
Tests the SerDes. This is the default. The port must be in diagnostics mode
to perform this test.
external
Tests both the SerDes and SFP. The port must be in diagnostics mode to
perform this test, and a loopback plug must be installed in the SFP.
online
Tests one online port.
cancel
Cancels the online test in progress.
status
Displays the status of a test in progress, or if there is no test in progress, the
status of the test that was executed last.
Examples
To run an internal (SerDes) or external (SFP) port test, do the following:
1.
To start an admin session, enter the following command and press the Enter
key.
2.
Place the port in Diagnostics mode, enter the following command (x = port
number) and press the Enter key.
3.
Insert the loopback plug into the SFP on the selected port.
4.
Choose type of port loopback test to run:
B-66
"Set Command" on page B-23
admin start
set port x state diagnostics
To run an internal loopback test, enter the following:
test x internal

for information about changing
59021-05 A