Process Interface; Pin Assignment - Fluke NORMA 4000 Operator's Manual

Power analyzer
Hide thumbs Also See for NORMA 4000:
Table of Contents

Advertisement

Process Interface

The Process Interface allows simultaneous analysis of the electrical and mechanical
power of up to four motors (generators). The torque and rotational speed are measured
via frequency inputs or as analog signals.

Pin Assignment

Figure 9-1 shows the Process Interface that is located on the rear panel of the Power
Analyzer (see "Design and Functions" in Chapter 3).
Pin
M1+...M4+
M1-...M4-
N1+...N4+
N1-...N4-
D1+...D4+
AGND
A1...A4
1
M 1+
N 1+
D 1+
M 2-
N 2-
M 3+
N 3+
D 3+
M 4-
N 4-
AGND
A 2
A 4
13
Figure 9-1. Process Interface Pin Assignment
Four inputs for torque; configurable for analog or digital signals
Four inputs for rotational speed; configurable for analog or digital signals
Four inputs for sensing rotation; only for motor analysis with digital speed inputs;
corresponding inputs, that is N1/D1 share a LO port
Analog ground input
Four analog outputs
NORMA Process Interface (Optional)
14
M 1-
N 1-
M 2+
N 2+
D 2+
M 3-
N 3-
M 4+
N 4+
D 4+
A 1
A 3
25
Assignment
9

Process Interface

esn063.eps
9-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Norma 5000

Table of Contents