Fluke NORMA 6003 User Manual

Fluke NORMA 6003 User Manual

Power analyzer
Hide thumbs Also See for NORMA 6003:
Table of Contents

Advertisement

Quick Links

NORMA 6003/NORMA 6003+/
NORMA 6004/NORMA 6004+
Power Analyzer
User Manual
July 2019 Rev 1
© 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice.
All product names are trademarks of their respective companies.

Advertisement

Table of Contents
loading

Summary of Contents for Fluke NORMA 6003

  • Page 1 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ Power Analyzer User Manual July 2019 Rev 1 © 2019 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.
  • Page 2 Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price.
  • Page 3: Table Of Contents

    Table of Contents Title Page Introduction ..............................1 Product Overview..............................1 How to Contact Fluke .............................. 2 Safety ................................3 Warning and Cautions ............................. 3 Symbols ................................... 4 Preparation ..............................5 Standard Packaging ..............................5 Stand and Hand Strap ............................. 7 Connect to the Power Supply ..........................
  • Page 4 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Select the Harmonics to Display ........................40 Linear and Logarithmic Axis .......................... 44 Phasor ................................... 45 Select the Phasor Data to Display ......................... 46 Select Circuit Type ............................47 Zoom Phasor ..............................47 Scope ..................................
  • Page 5 Electrical Specifications ............................81 Voltage ................................81 Accuracy ................................ 82 Current ................................82 Motor (NORMA 6003+、NORMA 6004+) ..................... 83 Frequency Domain Measurement ........................ 83 Appendix ............................... 84 Measurement Calculation Method ........................84 How to Make More Accurate Measurements ....................... 89 Measurement Error Caused by the Channel Resistance ................
  • Page 7: Introduction

    The Fluke NORMA 6003/NORMA 6003+/NORMA 6004/NORMA 6004+ Power Analyzers (the Product or Analyzer) are portable, precision wideband power analyzers. Use the product with the Fluke current clamp 80i-2010s and High Voltage Differential Probe U1500s for a broad range of electrical loads including those with electronic switching (inverter type).
  • Page 8: How To Contact Fluke

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual How to Contact Fluke To contact Fluke, call one of the following telephone numbers: Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe: +31 402-675-200 •...
  • Page 9: Safety

    Power Analyzer Safety Safety Warning and Cautions A Warning identifies hazardous conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. XW Warning To prevent possible electrical shock, fire, or personal injury and for safe operation of the Product: Read all safety information before you use the Product.
  • Page 10: Symbols

    This Product contains a lithium-ion battery. Do not mix with the solid waste stream. Spent batteries should be disposed of by a qualified recycler or hazardous materials handler per local regulations. Contact your authorized Fluke Service Center for Li-ion recycling information.
  • Page 11: Preparation

    Table 2 listed on the packing list. If there is any shortage of parts, please inform the nearest Fluke Technical Service Center or the place of purchase. If you need to reship the Product, please use the original package case. If the original package is not available, a new package can be ordered from Fluke according to the Product’s model and serial...
  • Page 12 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Table 2. Standard Equipment Quantity Item Description NORMA NORMA 6004/6004+ 6003/6003+ Main unit, including battery BP291: 3894688 Power Supply Adapter (18V DC, CAT IV 600V Adapter) Power line cord (for China): 4894155...
  • Page 13: Stand And Hand Strap

    Power Analyzer Preparation Stand and Hand Strap The Analyzer is portable and equipped with a tilt stand that allows the Analyzer to be placed on a flat surface for users to view the screen from a certain angle, as shown in Figure 2.
  • Page 14: Connect To The Power Supply

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Connect to the Power Supply Connect the Analyzer to a standard AC power supply according to Figure 4 and turn on the Analyzer: 1. Connect the connector end of the power cord to the power adapter/charger and insert the plug into a standard wall outlet.
  • Page 15: Battery Charging

    Power Analyzer Preparation Battery Charging To get enough battery power, you must first charge the Product. When powered by a battery, the battery symbol at the top of the screen indicates the condition of the battery. Symbol indicates low battery power, please charge the battery immediately. To charge the battery and power the instrument, connect the power adapter as shown in Figure 5.
  • Page 16: The Product

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual The Product This section describes the operation panel of the Product and the location and function of the display. Please read this section carefully before operating the Product. Refer to for instructions Control Panel on the front panel of the Product;...
  • Page 17: Operation Features

    Power Analyzer The Product Operation Features This section describes the Analyzer’s control panel and the functions and locations of the various interfaces and ports. Please read this section carefully before operating the Product. Control Panel list the features and functions of each component on the control panel. Figure 6 Table 4.
  • Page 18 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Table 4. Components on the Control Panel Item Description Power button The power button is also indicates the AC power connection. If the indicator light is lit, when the Product is off, that indicates that AC power is connected. The button is orange when the battery is being charged;...
  • Page 19 Power Analyzer The Product Item Description Interface buttons Hold/Run Push HOLD, the Product freezes the reading on the screen and the screen will not refresh until you push HOLD again. Although the screen is frozen, the Product continues to measure. Save/Logger - Short push: Save the current data or settings of the Analyzer.
  • Page 20: Display Screen

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Item Description Backlight - Short push: adjust the brightness of the backlight, which can be adjusted in multiple levels. - Push and hold for 2 seconds: capture the current screen and save it as a PNG format.
  • Page 21 Power Analyzer The Product Status Bar Table 5. Status bar Item Description Menu navigation Displays the menu path of the current screen, for example: Configure > Wiring. Clock Shows the current date and time of the Analyzer. Integration identifier When integrating, the status bar shows the integral indicator. See Integration details.
  • Page 22: Interface Panel

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Interface Panel Table 6. Connector Panel Item Description Voltage/current input channel number Current port protection cover The protective cover can slide back and forth. When the protective cover slides forward, the external current sensor input port is exposed; when the protective cover slides back, the current input port is exposed.
  • Page 23 Power Analyzer The Product Item Description Input port for motor speed / torque signal Signal Input for torque analog quantity, 10 V range Common port for torque input Input for speed analog quantity, 10 V range; or input for speed pulse, A pulse Input for speed pulse, pulse B Input for speed pulse, pulse Z Common port for speed input...
  • Page 24: Operation

    Item Sets the voltage/current range for each channel, ratio, filter, and selects Range whether to use an external sensor. NORMA 6003+ and NORMA 6004+ can also set the mode and ratio of the motor torque/speed measurement. for details Set Range Wiring Sets the wiring selection and the synchronization source of each wiring group.
  • Page 25 Power Analyzer Operation Table 8. Range Configuration Item Description Voltage range options: - Auto: Autorange. The Analyzer automatically selects the voltage measurement range with the best resolution. Vol. Range - 10 V - 100 V 1000 V Scale of an external voltage sensor (PT). After setting the scale of the external voltage sensor correctly, the Analyzer automatically calculates the actual voltage value of the measured signal based on the voltage scale and the measured value.
  • Page 26 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Item Description Current range options: Cur. Range - Shunt: Auto, 0.1A, when "Ext. Sensor" is not selected 1A, 10A ( - Ext. Sensor: Auto, 0.1V, 1V, 10V (when "Ext. Sensor" is selected) Choose whether to use an external sensor.
  • Page 27 Power Analyzer Operation 6. An input keyboard appears. Use the arrow ( M N O P ) keys to move the cursor over the corresponding character on the keyboard, then push ] (Select) to enter the value into the input box at the top. Repeat until all characters are entered. Note For the characters on the keyboard: k = ×10...
  • Page 28 Turn on this filter to easily observe the synthesis frequency of the frequency conversion system. If measuring a 3-phase system, Fluke recommends that the line filter settings for each channel in the 3-phase system should be consistent.
  • Page 29: Set The Wiring Selection

    Power Analyzer Operation Item Description Torque Mode: The torque input is 0 V to 10 V the supported input signals must be conditioned to operate within these limits. If the sensor has a current output this must be converted using a shunt resistor before applying to the input.
  • Page 30 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual 1P2W1M Figure 8. 1P2W1M Wiring For 1P2W1M wiring, connect a voltage measurement channel between the phase line and the zero line; connect a current measurement channel in series with the phase line or the zero line (note the direction) or clamped on the phase line or the zero line with a current sensor.
  • Page 31 Power Analyzer Operation measure the parameters between the zero and ground line (NORMA 6004/6004+ only). If the ground and zero lines do not exist, connect the common ends of the 3 channels together and suspend, and the total power measured is still valid. For this wiring system: 1.
  • Page 32 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual 4. The zero line current can be measured by summing 3 current channel, but the zero line voltage cannot be measured. When the zero line voltage/zero line current is present, the total power measured is also inaccurate.
  • Page 33 Power Analyzer Operation Wiring System Comparison 3P4W3M 3P3W3M 3P3W2M Number of channels occupied Balanced test impedance The power frequency components of frequency conversion systems can be eliminated Direct Indirect Indirect Phase voltage measurement calculation calculation Indirect Direct Partial direct Line voltage calculation measurement measurement...
  • Page 34 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Figure 12. Wiring Note The optional wiring selection is related to the number of channels equipped with the Analyzer, and the interface of wiring selection will be different. Proper selection of wiring is conducive to ensuring more accurate measurements.
  • Page 35: Set Sync Source And Update Rate

    Power Analyzer Operation Make a Wiring Selection: 1. In the Wiring screen (Figure 12), use the left and right arrow ( O P ) keys to select a channel or wiring group in “Channel Configuration”. The wiring selection of the selected channel/wiring group is highlighted.
  • Page 36: Zero

    In general, the voltage of the power frequency system is more stable than the current. Fluke recommends using the voltage as the sync source. The voltage of the frequency conversion system has a large high-frequency component, while the high- frequency component of the current is relatively small.
  • Page 37: Define Calculation Formula

    Power Analyzer Operation Define Calculation Formula The Analyzer allows the user to define efficiency and some numerical calculation formulas. Define Efficiency Calculation Formula The Analyzer allows the user to edit the efficiency calculation formula. The user can set the input and output power source of the system to be measured and calculate the efficiency.
  • Page 38 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Item Description Operators and buttons Operators of addition and subtraction Delete key Delete a symbol before the cursor. Clear key Clear all characters in the input box. OK key Accept the current input and go back.
  • Page 39 Power Analyzer Operation Define hvf/hcv Calculation hvf/hcv is a numerical measurement item used for measuring rotating motors according to IEC60034. It is necessary to configure the type of motor and rated voltage/current according to the actual test requirements. 1. From the Main screen of any view mode select (Configure) >...
  • Page 40: Meter

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual corresponding input box, then push ] (Select), and input the corresponding value using the on-screen keyboard, then move the cursor to OK key on the keyboard, and push ] (Select). 5. Repeat step for hcf settings.
  • Page 41: Preview

    Power Analyzer Operation Item Description Soft Keys (Configure): Global configuration, see Global Configuration. (Preview): Enter Preview mode, see Preview. (User Item): Enter User-defined Mode, see User Item View. (Integral): Integration Operation, see Integration. Bottom Bar Displays the current page number or prompts the user for an action to take. Preview In Preview mode, all currently available measurements are shown in a certain order on the screen.
  • Page 42: User Item View

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Item Description Page up key When the number of measurements available exceeds the number of items displayed on each screen, the keys can be used to scroll forward or backward to display more measurements.
  • Page 43 Power Analyzer Operation Item Description Move backward the currently selected item Moves the currently selected measurement forward by one position in the list. If the currently selected measurement is already at the end of the list, no action is taken when the button is pushed. Note When you enter the User Item view for the first time, the screen is blank, there are no measurements in the list.
  • Page 44: Integration

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Delete Measurement Items 1. From the main screen of Meter select C (User Item). 2. Use the arrow ( M N O P ) keys to move the cursor to the measurement item you want to delete.
  • Page 45: Harmonic

    Power Analyzer Operation Table 15. Integral Item Description Start Starts integration. Integration will start immediately after the button is pushed. Stop Stops integration. Integration will stop immediately after the button is pushed. (This label does not display anything when the integral is not in progress. ) Reset Clears the integral values and integral time.
  • Page 46: Change View Mode

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Item Description Total Harmonic Distortion Total harmonic distortion of the voltage or current of the currently item, U or I The unit is%。 Fundamental Content Fundamental content of the voltage or current of the currently selected Item, U or I The unit is %.
  • Page 47 Power Analyzer Operation Harmonic Table lists the items shown in the table. Table 17 Table 17. Harmonic Table Item Description Harmonic Harmonic Order Order Magnitude Harmonic magnitude, absolute value, in V or A. Percentage Harmonic percentage, relative to fundamental wave. Phase Harmonic phase angle, relative to fundamental wave.
  • Page 48 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Harmonic Bar The harmonic bar is as shown in Figure 14 where the horizontal axis represents the harmonic order and the vertical axis represents the harmonic amplitude in V or A. The harmonic bar of each screen shows 50th harmonics. The pages can be turned forward or backward through (PG DN) button to display more harmonic bar.
  • Page 49 Power Analyzer Operation The harmonic FFT is as shown in 15, where the horizontal axis represents frequency and the Figure vertical axis represents magnitude. Use the left and right arrow ( O P ) keys to scroll the horizontal axis to see FFT curves at more frequencies.
  • Page 50: Linear And Logarithmic Axis

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Linear and Logarithmic Axis In the harmonic bar and FFT view, use (AXIS) button to switch the vertical axis to linear ( or logarithmic axis ( Figure 16. Harmonic – Logarithmic Axis...
  • Page 51: Phasor

    Power Analyzer Operation Phasor The Phasor mode displays the magnitude and phase relationship of the voltage and current of each phase in the selected wiring group in tabular and graphical form. Enter Phasor Mode: From the Current measurement screen select (Phasor) •...
  • Page 52: Select The Phasor Data To Display

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Item Description Voltage unbalance The 3-phase voltage unbalance of the currently selected wiring group. Current phasor information The current phasor information of each phase in the selected wiring group, including fundamental amplitude and phase angle relative to sync source. See Select the Phasor for details.
  • Page 53: Select Circuit Type

    Power Analyzer Operation Enter Wiring Group Menu From the main screen of Phasor select B (Wiring Group). • Select the Phasor Data to Display 1. In Wiring Group, use the left and right arrow ( O P ) keys to select a channel or wiring group in Channel Configuration.
  • Page 54 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Table 19. Zoom In/Out Vector Item Description Select the Phasor to Zoom Push A (ZOOM) to cycle through the currently selected phasor, namely U ZOOM or I. The currently selected phasor is displayed under the “ZOOM” softkey, such as , which means the currently selected phasor is voltage.
  • Page 55: Scope

    Power Analyzer Operation Scope The Scope mode is used to view the waveform of the signal under measurement. The supported signals include voltage and current etc. Up to 4 signals can be selected simultaneously for waveform display. In addition, the Product provides cursor measurement function that can be used for various measurements or calculations of waveforms.
  • Page 56 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Table 20. Scope Screen Description Item Status Bar Status Bar for details. Difference between cursors / average at cursor - The difference between the 2 cursors is displayed when the double horizontal cursors are activated.
  • Page 57: Select The Waveform To Display

    Power Analyzer Operation Item Description Horizontal Axis Scale Horizontal axis (the time axis) scale, the length of time represented by each grid Horizontal axis supports manual zoom. See and Shift the Waveform for details. Zoom Trigger Source and Trigger Mode Current trigger setting, showing the current trigger source and trigger mode.
  • Page 58: Trigger Setup

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Trigger Setup Use Trigger to determine when the Analyzer should start displaying waveforms on the screen so that the waveforms displayed by each refresh can be aligned. Once the set trigger condition is met, the screen is triggered, the waveform displayed on the screen is aligned at that point.
  • Page 59: Measure With The Cursor

    Power Analyzer Operation Trigger Setup: 1. From the main screen of Scope select C (Trigger). 2. Push A (Source) until the block with the same color as the waveform of the trigger signal is shown. 3. Push B (Method). 4. Use the up and down arrow ( M N ) keys to move the cursor to the Type drop down box and push ] (Select) on the control panel.
  • Page 60 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Item Description Move the cursor Each time you push C , the currently selected cursor will be cycled through. Move The selected cursor is indicated in yellow and is displayed below the “Move”...
  • Page 61: Zoom And Shift The Waveform

    Power Analyzer Operation Zoom and Shift the Waveform The Scope supports horizontal and vertical zooming and shifting. You can select a singe waveform independently for vertical zooming and shifting and the waveforms are not affected by each other. Enter the Zoom Menu: From the main screen of Scope select E (Zoom/Shift).
  • Page 62: Trend

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Trend The Trend mode displays and records the trend of numerical measurements. Any numerical measurement item can be displayed as a trend, up to 4 trend curves can be displayed simultaneously on the screen.
  • Page 63 Power Analyzer Operation Table 24. Trend Screen Item Description Status Bar for details. Status Bar Vertical Axis Scale Displays the vertical axis scale of each trend waveform on the current screen, which is the value represented by each grid. The left side is the item symbol, and the right side is the vertical axis scale of its trend curve.
  • Page 64: Select The Trend To Display

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Select the Trend to Display Up to 4 Trend curves can be displayed simultaneously on the screen, and the user can select 1 to 4 items from all available items for display.
  • Page 65 Power Analyzer Operation Add Trend Item: 1. From the main screen of Trend select B (ITEM)> B (Add). The Add menu is shown. All available items are listed by categories in a tree structure. The available trend items contain the most measurement items under Meter function. 2.
  • Page 66: Set Measurement Period

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Set Measurement Period The measurement period is the time interval used to plot the trends and provides two modes of “Update Rate” and “Interval”. In the “Update Rate” mode, the interval of the trends is the update rate of the Analyzer, which can achieve accurate evenly spaced acquisition, which is suitable for analyzing the process of rapid change;...
  • Page 67: Zoom And Shift The Trend

    Power Analyzer Operation Zoom and Shift the Trend The Trend supports vertical and horizontal shifting as well as vertical zooming. Each trend graph can be shifted and zoomed vertically independently, and they are not affected by each other. Enter the Zoom Menu: From the main screen of Trend select E (Zoom/Shift).
  • Page 68: Data Management

    Meter mode for a long time. The data can be downloaded to a PC by using the Fluke Power Analyzer software. For more information, please refer to the instructions for using the PC software.
  • Page 69: Logger Memory

    Power Analyzer Operation Logger Memory Push (Memory) to enter “Logger Memory” interface. The functions in the menu are shown Table Table 28. Memory Data Management Item Description Data View and manage saved data files. Logger Sessions View and manage Logger items. Screen Captures View and manage saved screenshot files.
  • Page 70 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Table 29. Memory File Operation Item Description Delete a file Del All Delete all files of the current type. The Analyzer uses an automatic naming method when saving files. With this Rename function key, the user can rename each file to a name that is easy to remember.
  • Page 71: Dual-Unit Interconnection

    Power Analyzer Operation Dual-Unit Interconnection The Analyzer supports Dual-Unit Interconnection, that is, 2 Analyzers work synchronously in host/slave mode to realize 6-channel or 8-channel channel configuration. Figure 21. Dual-Unit Interconnection Dual-Unit Interconnection Connection 2 Analyzers are connected in a point-to-point manner by using the RS-485/sync adapter provided with the Analyzer to connect the RS-485 communication ports on the right side of the 2 Analyzers, which are 3-pin connector sockets, as shown in the Figure...
  • Page 72: Dual-Unit Interconnection Measurement

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Dual-Unit Interconnection Measurement After 2 Analyzers are connected via the RS-485 port, follow the these steps to make measurements: 1. Set RS-485 communication parameters of the slave. a) From the main screen in any operating mode of the slave, select (SYSTEM) >...
  • Page 73: Connect The Computer

    Power Analyzer Operation Connect the Computer The Fluke Power Analyzer software is a software that communicates between the Analyzer and PCs via RS-485 or mini-USB interfaces. With this software, data can be controlled and summarized simply and quickly via the PC.
  • Page 74: System Settings

    All information listed in the work area of the System screen is reference information and cannot be changed. This information is useful for troubleshooting and maintenance. Note Please have this information ready when contacting Fluke for technical support. Table 30. System Information...
  • Page 75: General Settings

    Power Analyzer System Settings General Settings The Settings screen contains some general instrument settings such as interface language, time and date, date format, log storage settings, as well as firmware upgrades and factory resets. Enter the Settings screen: From the Main screen in any operating mode select (SYSTEM) >...
  • Page 76: Logger Memory

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Logger Memory The user can select the operation mode of the Analyzer when the memory is full, which can be set to stop the logging by the system, to manually clear log files saved in the Product by the user, or to automatically overwrite the old files by the system.
  • Page 77: Remote

    Power Analyzer System Settings Item Option 9600 19200 38400 57600 Baud Rate 115200 230400 460800 576000 921600 CRLF 7 Bits Data Bits 8 Bits 1 Bits Stop Bits 1.5 Bits 2 Bits Device address 1 to 9 Note To ensure proper communication between the host/slave Analyzer, you must configure Dual-Unit Interconnection.
  • Page 78: Calibration

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Table 32. Diagnosis Item Description LCD Test Push , the screen will show alternately full-screen of solid colors of blue, black, white, red and green. Push Q (Back) to go back to the test menu.
  • Page 79: Maintenance

    How to Contact Fluke Accessories and Options. XW Warning To prevent electric shock, remove all probes, test leads and accessories before the battery compartment cover is opened. Be sure to use a Fluke specified battery for replacement. Please refer to Figure...
  • Page 80 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Figure 23. Change the Battery To Change the Battery: 1. Turn off the Product, unplug the power adapter/charger from the power jack, and disconnect all test leads. 2. Place the Product's operating panel face down on a flat table and lift the stand or remove it from the Product.
  • Page 81: Change The Fuse

    Do not incinerate the product and/or the battery. Change the Fuse Please refer to Figure Figure 24. Change the Fuse Caution To prevent damage to the instrument, use only the fuses specified by Fluke. See to Contact Fluke Accessories and Options.
  • Page 82: Firmware Upgrade

    The firmware upgrade of the Product is very convenient and can be completed by using the USB memory containing the new firmware. Please download the last firmware package from www.fluke.com, then extract and copy the files to a USB memory. For more details, please refer to the documentation provided with the firmware package.
  • Page 83 Power Analyzer Maintenance Figure 25. Firmware Upgrade 1. Open the cover of the battery compartment as specified in the section Change the Battery. 2. There is a USB port on the upper right side of the battery compartment. Plug the USB memory containing the new firmware into the USB port.
  • Page 84 Note To ensure the success of the upgrade, the battery must be installed during the firmware upgrade and the battery level must be at least 50%. The power adapter must be connected. Please find the latest firmware on www.fluke.com.
  • Page 85: Accessories And Options

    Test leads, 1.5 m, (4) red, (4) black, (8) blue 5098494 Alligator clips, (4) red, (4) black, (8) blue Teat lead set, NORMA 6003/6003+ kit Test leads, 1.5 m, (3) red, (3) black, (6) blue 5098502 Alligator clips, (3) red, (3) black, (6) blue...
  • Page 86: Specifications

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Specifications General Specifications Size (HxWxL)........298 mm x 215 mm x 96 mm Weight ..........3.5 kg Display ..........5.7" TFT LCD, 640x480 pixels Maximum voltage between any Terminal and Earth Ground…......1000 V Temperature Operating Temperature ....
  • Page 87: Electrical Specifications

    This product is considered an exempt device per clause 15.103. Electrical Specifications Modules NORMA 6003 ......3 Voltage + 3 Current NORMA6003+ ......3 Voltage + 3 Current + 1 Motor NORMA 6004 ......4 Voltage + 4 Current NORMA 6004+ ......4 Voltage + 4 Current + 1 Motor Sample Rate ........
  • Page 88: Accuracy

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Accuracy Accuracy (% reading + % range) Range 10 Hz to 1 kHz 10 kHz 0.1 + 0.1 0.1 + 0.1 5 + 0.5 1000 V 0.1 + 0.1 0.1 + 0.1 5 + 0.5...
  • Page 89: Motor (Norma 6003+、Norma 6004+)

    0.1 + 0.1 5 + 1 0.1 + 1 0.1 + 0.5 5 + 1 0.1 V Motor (NORMA 6003+ NORMA 6004+) 、 Voltage Range ........±10 V dc, 10 % overload Voltage Channels ......2 Input Impedance ........ 1.1 MΩ (Typical) Temperature Coefficient ....
  • Page 90: Appendix

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Appendix Measurement Calculation Method Measurement Function Calculation Formula = � ���� = � ���� ���� ���� ������������ ������������ ���� + ���� + ���� ���� + ���� + ���� ���� ���� ���� ����...
  • Page 91 Power Analyzer Appendix Measurement Function Calculation Formula = arg [���� ( 1 ) ] = arg [���� ( 1 ) ] φU φI ����01 ����01 Fundamental Phase Relative to the sync source Relative to the sync source � ���� � ���� −...
  • Page 92 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Measurement Function Calculation Formula ���� = ���� � ���� − ���� s = +1 when inductive;s = -1 when capacitive Reactive Power ���� = ����� − ���� Σ Σ Σ ( 1 ) ����...
  • Page 93 Power Analyzer Appendix Measurement Function Calculation Formula ���� ����01 ���� ����01 ����01 Fundamental Impedance ���� ���� ���� ���� ���� ���� Impedance Series ������������ ������������ Equivalence ���� ���� ����01 ����01 ���� ���� ��������01 ��������01 Fundamental Impedance ����01 ����01 Series Equivalence ���� ����...
  • Page 94 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual Measurement Function Calculation Formula 2���� ���� ������������������������ ∙ �������������������� ���� Mechanical Power ���� ���� � ���� �������� �������� 3600 ���� ���� Mechanical Energy...
  • Page 95: How To Make More Accurate Measurements

    Power Analyzer Appendix How to Make More Accurate Measurements Measurement Error Caused by the Channel Resistance By wiring a circuit to match the load, you can minimize the effects of power loss on measurement accuracy. The wiring of the source and load is discussed in this section. Connect the voltage measurement circuit near the load (as shown in 1).
  • Page 96: Effects Of Leakage Capacitance

    NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual when the load voltage e is 250V or more, the effect on the measurement accuracy is less than 0.1%. In summary, when measuring low voltage and large current, it is recommended to use the wiring method of the figure above;...
  • Page 97: Broadband Measurement

    Power Analyzer Appendix Effects of Leakage Current on Current Measurement Methods to Reduce the Effect of Leakage Capacitance 1. High frequency components more easily generate current on the leakage capacitance than low frequency components. When measuring the small current with the built-in current channel, if you do not pay attention to the high-frequency components of the current, it is recommended to turn on the 650Hz line filter to effectively reduce the effect of leakage capacitance.
  • Page 98 NORMA 6003/NORMA 6003+/ NORMA 6004/NORMA 6004+ User Manual...

This manual is also suitable for:

Norma 6003+Norma 6004