Cleaning The Air Filter - Maytag 23-11-2251N-004 Installation Manual

Through-the-wall room air conditioners
Table of Contents

Advertisement

Available languages

Available languages

Cleaning
the air filter
EVERY TWO WEEKS:
Clean the filter.
1. Turn Power OFF.
2. Remove the air filter by grasping the top corners and pulling
it up and out of the unit.
(Fig. 15)
3. Wash in hot soapy water, rinse and shake dry.
4. Replace the filter with the front of the filter toward
you.
5. To dry the filter thoroughly,
run your unit in fan mode for a
few minutes.
Remember, only a clean filter
works properly
and delivers top efficiency
at every setting.
Note:
Failure to keep air filter
clean will
result
in poor air
circulation.
DO NOT operate
without
filter. This can render the
unit inoperative.
Proper use and care of your
air conditioner
will
help ensure
longer
life
of the
unit.
It
is recommended
to
have
a
professional
annually
inspect
and
clean
the
coils
and
condensate
water
passages. Expense of annual
inspection
is
the consumer's
responsibility.
m
Decorative
front
Troubleshooting
Guide
Occurrence
Air conditioner will not operate
Air from unit does not
feel cold enough
Air conditioner cooling,
but room is too warm --
ice forming on cooling coil
tion.
behind decorative front
Air conditioner cooling,
but room too warm --
To save time and expense, check the following
before calling an authorized service station.
Solutions
Possible
Cause
• Wall plug disconnected.
• House fuse blown or circuit breaker tripped.
• Unit turned off and then on too quickly.
• Thermostat set too low for cooling.
• Thermostat set too warm.
• Room temperature below 70°E
• Outdoor temperature below 70°E
• Dirty air filter -- air restricted.
• Dirty air filter -- air restricted.
Push plug firmly into wall outlet.
Replace fuse with time delay type
or reset circuit breaker.
If air conditioner is turned off,
wait 3 minutes before restarting.
Adjust thermostat to higher setting for cooling.
Set thermostat to colder temperature.
Cooling may not occur until room
temperature rises above 70°E
To defrost the coil set thermostat to warmer
position.
Clean filter. See "Cleaning the Air Filter" sec-
Cleanair filter.
Referto "CleaningAir Filter" section.
no ice forming on cooling coil
behind decorative front
Noise when unit is cooling
Water dripping inside
when unit is cooling
Water dripping outside
when unit is cooling
• Thermostat set too warm.
• Air movementsound.
• Soundof fan hitting water-moisture
removal system.
• Window vibration -- poor installation.
• Improper installation.
• Unit removing large quantity of moisture
from humid room.
Set thermostat to colder setting.
Thesound of rushing air is normal. If too loud,
turn selector to lower fan setting.
This is normal when humidity is high.
Closedoors,windows and registers.
Referto installation instructions--
checkwith installer.
Tilt air conditioner slightly to the outside to
allow water drainage. Refer to installation
instructions -- check with installer.
This is normal during excessivelyhumid days.
12

Advertisement

Table of Contents
loading

Table of Contents