Upgrade and Troubleshooting Procedures
Adding a Front Panel Controller to an existing system
Figure 5-1.A
5-1
The following procedures may be done in the field.
•
Add Front Panel Controller (FPC 1000) - see below.
•
Installing a Software Upgrade - see Page 5-3.
•
Swapping RS-232 / RS-422 Ports - see Page 5-4.
•
Troubleshooting a system problem - see Page 5-5.
•
Adding Video cards to a Matrix 3200/6400 Video Switcher- see Page 5-7.
•
Adding BMEs to a Matrix 6400/3200 System - see Page 5-9.
Adding a Front Panel Controller to an existing system involves replacing the blank
Access Panel on any BME (except Sync) with the FPC 1000 panel. A system
can only have one Front Panel Controller and it must be installed on BME #0. The
details for installing the FPC 1000 are included in the User's Manual provided with
the unit.
RGB
MUTE
AUDIO
MUTE
INPUTS
BME
-
4
+
ADDRESS
A
B
IN
1
9
17
C
D
E
SYNC
A
2
10
18
B
C
D
OUT
E
3
11
19
4
12
20
ANAHEIM, CA
MADE IN USA
5
13
21
IN
OUT
6
14
22
AC POWER INPUT
FUSE: 250V 5.0A TT
7
15
23
8
16
24
Matrix 6400 Video BME Front and Rear Panels
Chapter 5 • Upgrades and Troubleshooting
POWER SUPPLIES
COMMUNICATIONS
+V
-V
RS232
BME
PRIMARY
TX
REDUNDANT
RX
DIAGNOSTICS
OUT
OUT
OUT
25
33
41
49
57
26
34
42
50
58
27
35
43
51
59
28
36
44
52
60
29
37
45
53
61
30
38
46
54
62
31
39
47
55
63
32
40
48
56
64
1 - 8
9 - 16
17 - 24
Extron • Matrix 3200/6400 Series • User's Manual
FPC-1000
SYSTEM
STATUS
REMOTE
MATRIX 6400
VIDEO
OUTPUTS
OUT
OUT
OUT
OUT
OUT
25 - 32
33 - 40
41 - 48
49 - 56
57 - 64