3Com PathBuilder S200 Series Owner's Manual page 112

3com switch owner manual
Hide thumbs Also See for PathBuilder S200 Series:
Table of Contents

Advertisement

LLC2 Local Termination
Configuring the LT
WAN Parameters
108
Local SAP
Range:
01 to FE (hexadecimal)
Default:
04
Description:
This SAP must match the source SAP of the frame received from
the LAN port for the session to be spoofed.
If you are using Local Termination Autolearn, specify the remote
Host SAP for the local MAC.
Boot Type:
LLC LT Station
LLC Profile Name
Range:
0 to 8 (alphanumeric, space blanks field)
Default:
(Blank)
Description:
Local Term Station Table references this parameter for the T1, T2,
TI, N2, N3, and TW values. If no profile name is specified, then
default values are used.
Boot Type:
LLC LT Station
These parameters make up the LT WAN Parameters Table.
T1Reply Timer
Range:
1 to 25 (seconds)
Default:
3
Description:
This Ack timer is used by a station to detect a failure of the remote
station to acknowledge an outstanding I frame or supervisory
frame with the pole bit set to 1.
Boot Type:
LLC LT WAN Parameters.
T2 Rx Ack Timer
Range:
1 to 255 (tenths of seconds)
Default:
1
Description:
The Receive Ack timer is used by a station to determine how long
it will withhold acknowledgment of a frame from the remote
station that requires acknowledgment. This is a method of
reducing the amount of acknowledgments generated by a link
station. When this timer expires, the link station should
immediately send an acknowledgment for all received frames not
yet acknowledged.
Bridging

Advertisement

Table of Contents
loading

Table of Contents