Heat Pumptemperature Lockouts; Dehumidification Droop Control; Special Heat Pump Operation - Honeywell VisionPRO 8000 Owner's Manual

Visionpro 8000 series touchscreen programmable thermostat
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

VisionPRO
TM 8000
Touchscreen
Programmable
Thermostat
Control DehumidificationSetting (Select Models)
Select
models
read the inside
humidity
level and allow for a
dehumidification
setting:
1.
Press the More key until the inside humidity
percent
and
dehumidification
setpoint
are shown.
Inside
_
.TJ.TJ
-IC
Humidity
DEHUMIDIFIER
M19967
2.
Use Up and Down arrow
keys, located
to the right of the
dehumidifier
setpoint,
to set desired
humidity
level
for
dehumidification
in the summer.
3.
Press Done key.
DehumidificationDroopControl
The dehumidification
control
attempts
to control
to the user's
humidity
setpoint
by turning
on the air conditioner.
In
extremely
high humidity
conditions,
the thermostat
keeps the
air conditioner
running
(energizing
Y and G) for up to 3°F
below
the temperature
setpoint.
It does this while trying
to
achieve
the desired
humidity
setpoint
and balancing
that with
the temperature
setpoint.
The thermostat
controls
up to 3 ° F
below
the temperature
setting
until either
the humidity
is
satisfied
or conditions
change.
Special Heat Pump Operation
Heat Pump LED Indication (Requires 24 Vac
Common Connection)
A red LED indication
is located
in the upper
right corner
of the
thermostat.
It is only visible
when
lighted.
When
the L terminal
is wired
to an equipment
monitor,
the
LED signals
when a check
or fail signal
is sent to the
thermostat
from the system.
This is operational
in the Heat,
Off, Cool or Auto positions.
See Fig. 32.
_/_L_
TO C
_/
EOU PMENT
/
MONITOR
TO R
M19907
Fig. 32. L terminal
switch
to R (power)
side of system
transformer.
Heat Pump Emergency Heat LED Indication
(Requires24 Vac Common Connection)
The thermostat
uses a red LED indicator
that lights when the
thermostat
is in the Emergency
Heat mode.
The LED is
located
in the upper right corner
of the thermostat.
It is visible
only when on. When
the thermostat
is in the Em. Heat system
mode,
the L terminal
is continuously
energized
and the LED is
on.
Heat PumpTemperature Lockouts
Dual Fuel Heat Pump and Outdoor Temperature
Sensor
In this operation,
there
is no external
fossil fuel kit (dual fuel
kit) installed;
the thermostat
controls
this function.
1.
Choose
correct
heat pump application
in Installer
Setup
Number
0170.
2.
Choose
Fossil
Fuel Option
as the backup
heat source
in installer
Setup
Number
0200.
3.
Choose
No External
Fossil
Fuel
Kit Option
is control-
ling back up heat in Installer
Setup
Number
0210.
4.
Choose
Outdoor
Temperature
Sensor
for Heat Pump
Temperature
Lockouts
Option
in installer
Setup
Num-
ber 0340.
5.
Choose
appropriate
Balance
Point
Temperature
in
installer
Setup
Number
0350.
OPERATION IN HEAT MODE ABOVE BALANCE POINT (OUTDOOR
TEMPERATURE)
When
the outdoor
temperature
is above
the selected
Balance
Point Temperature
(ISU 0350),
only the compressor
operates
and the fan (G terminal)
energizes
when the thermostat
calls
for heat. See Fig. 33.
LU
F-
LU
[3_
LU
F-
o
o
£3
F-
o
30
COMPRESSOR
ONLY
FOSSIL FUEL ONLY
BALANCE
POINT
M22441
Fig. 33. Dual Fuel Heat Pump Operation in Heat mode with
Balance Point Set.
OPERATION IN HEAT MODE BELOW BALANCE POINT (OUTDOOR
TEMPERATURE)
When
the outdoor
temperature
is below
the selected
Balance
Point Temperature
(ISU 0350),
only the Fossil
Fuel (auxiliary
heat) operates
and the fan (G terminal)
does not energize
when the thermostat
calls for heat.
33
68-0280