Honeywell VisionPRO 8000 Owner's Manual page 18

Visionpro 8000 series touchscreen programmable thermostat
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

VisionPRO
TM 8000
Touchscreen
Programmable
Thermostat
Table
3. Installer
Setup
Menu.
(Continued)
Installer
Setup
Number
0360
O38O
0500
0510
0520
0530
0540
Installer
Setup
Name
Heat Pump
Auxiliary
Lockout
Indoor
Dehumidification
Control
Furnace
Change
Reminder
Humidifier Pad
Replacement Reminder
UV Lamp Replacement
Reminder
Adaptive
Intelligent
Recovery
TM
Number
of Periods
Settings
0--no
auxiliary
heat lockout.
40°F (4.5°C)
45°F (7°C)
50°F (10°C)
55°F (13°C)
60°F (15.5°C)
0--No
indoor
dehumidification
control.
l--Dehumidification
control
activated.
0--furnace
filter reminder
off
1--10
run time days
2--30
run time days
3--60
run time days
4--90
run time days
5--120
run time days
6--365
run time days
0--humidifier
pad replacement
reminder
off
1--90
calendar
days
2--180
calendar
days
3--365
calendar
days
0--UV
lamp replacement
reminder
off
1--365
calendar
days
lmAdaptive
Intelligent
Recovery
TM
control
is activated
(system
starts
early so setpoint
is reached
by start of
program
period).
0--Conventional
Recovery
(system
starts recovery
at
programmed
time)
2--two
periods
available
(Wake
and Sleep)
4
four periods
available
(Wake,
Leave,
Return
and
Sleep)
Notes
Shown
if electric
is
chosen
for backup
heat
source
and outdoor
temperature
sensor
for
control
is selected.
(See
Advanced
Features
section
for more
information.)
Available
on select
models.
If dehumidification
control
is activated
and auto-
changeover
is selected
in
Installer
Setup
Number
0300,
the deadband
minimum
is defaulted
to
5°F (3°C) in Number
0310.
Run time based on call for
fan.
Not shown
if non-
programmable
is
selected.
2 or 4 applies
to
all days of the week.
0580
Minimum
Compressor
5--five-minute
compressor
off-time
setting
(factory
--
Off Time
setting)
0, 2, 3, 4--other
compressor
off-time
settings
0600
Heat Temperature
40-90--temperature
range (1 °F increments)
of heating
Shown
in 1t2 °C.
Range
Stop
setpoint.
0610
Cool Temperature
50-99--temperature
range (I°F
increments)
of cooling
Shown
in 1/2 °C.
Range
Stop
setpoint.
0640
Clock
Format
12--12
hour clock (factory
setting)
24--24
hour clock
68-0280
18