Honeywell VisionPRO 8000 Owner's Manual page 39

Visionpro 8000 series touchscreen programmable thermostat
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

VisionPRO
TM 8000
Touchscreen
Programmable
Thermostat
Table
14. Troubleshooting.
(Continued)
Symptom
Action
Heat pump puts out cool air in
Set Changeover
Valve
(installer
Setup
the heat mode
and warm air in
Number
0190) to match
the changeover
the cool mode.
required
by the installed
heat pump.
Both the heating
and cooling
equipment
are running
at the
same time.
Possible
Cause
Changeover
Valve
(Installer
Setup
Number
0190)is
not configured
to
match
the changeover
required
by the
installed
heat pump.
The heating
equipment
is not a heat
pump
but the System
Type
(installer
Setup
Number
0170)
is set to Heat
Pump.
Heating
and cooling
wires are shorted
together.
Heating
equipment
is not a heat pump
but System
Type
(installer
Setup
Number
0170)
is set to Heat Pump.
Heating
equipment
is not a heat pump
but System
Type
(installer
Setup
Number
0170)
is set to Heat Pump.
Set System
Type
(installer
Setup
Number
0170) to match
the installed
heating
and/or
cooling
equipment.
Separate
the shorted
heating
and cooling
wires.
Heating
equipment
is running
Set System
Type
(installer
Setup
Number
in the cool mode.
0170) to match
the installed
heating
and/or
cooling
equipment.
Heating
equipment
does not
Set System
Type
(installer
Setup
Number
turn off and heat temperature
0170) to match
the installed
heating
and/or
setting
is set below
room
cooling
equipment.
temperature
(Heat On is not in
the display).
Cannot
set the system
setting
System
Type
(installer
Setup
Number
Set System
Type
(installer
Setup
Number
to Heat.
0170)
is set to Cool Only.
0170) to match
the installed
heating
and/or
cooling
equipment.
Cannot
set the system
setting
System
Type
(installer
Setup
Number
Set System
Type
(installer
Setup
Number
to Cool.
0170)
is set to Heat Only or Heat Only
0170) to match
the installed
heating
and/or
with Fan.
cooling
equipment.
Heat On is not in the display.
System
setting
is not set to Heat and/or
Set the system
setting
to Heat and set the
temperature
setting
is not set above
temperature
setting
above
the room
room temperature,
temperature.
Cool On is not in the display.
System
setting
is not set to Cool and/or
Set the system
setting
to Cool and set the
the temperature
setting
is not set below
temperature
setting
below
the room
room temperature,
temperature.
Wait is in the display.
Compressor
minimum
off timer
is
Wait up to five minutes
for the cooling
or
active,
heating
(heat pump)
equipment
to turn on.
"Screen
Locked"
appears
on
The keypad
is fully or partially
locked.
Check
installer
Setup
Number
0670
to
the screen
and all or some of
change
keypad
locked
options.
the keys do not respond.
39