Honeywell VisionPRO 8000 Owner's Manual page 17

Visionpro 8000 series touchscreen programmable thermostat
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

VisionPRO
TM 8000
Touchscreen
Programmable
Thermostat
Table
3. Installer
Setup
Menu.
(Continued)
Installer
Setup
Number
0260
O27O
Installer
Setup
Name
Cycles
per hour (cph) for
3rd Stage
Heat
(Aux Heat for 3H/2C
Heat Pumps)
Cycles
per hour (cph) for
Em Heat
Settings
1--1
cph used for steam
and gravity
3--3
cph for hot water
systems
and high efficiency
(90%
or better)
furnaces
5--5
cph for standard
fossil fuel forced
air (less than 90%
efficient)
systems
(factory
setting)
9--9
cph used for electric
furnaces
or electric
auxiliary
heat for heat pump
systems
2, 4, 6, 7, 8, 10, 11, 12--other
cycle
rate settings
3--3
cph for hot water
systems
and high efficiency
(90%
or better)
furnaces
5--5
cph for standard
fossil fuel forced
air (less than 90%
efficient
or better)
systems
9--9
cph for electric
strip heat for heat pumps
0--Backlight
not on continuously.
Thermostat
backlight
comes
on with each key press.
l--Backlight
is on continuously
(thermostat
must have a
common
wire attached
for this function).
Notes
Only shown
if 3H/2C
heat pump
is selected.
Only shown
if 2H/1C
or
3H/2C
heat pump
is
selected.
0280
Continuous
Backlight
Option
is always
shown;
however,
continuously
on
backlight
works
only if
thermostat
is wired with
24 Vac Common.
0300
Changeover
0310
Deadband
Shown
only if automatic
changeover
is selected.
0--manual
changeover
(factory
setting)
l--auto
changeover
Heating
and cooling
setpoints
can be set no closer than
chosen
value:
2--2°F
(1.5°C)
3--3°F
(2°C)
4--4°F
(2.5°C)
5--5°F
(3°C)
6--6°F
(3.5°C)
7--7°F
(4°C)
8--8°F
(4.5°C)
9--9°F
(5°C)
0--fahrenheit
temperature
display
(factory
setting)
l--celsius
temperature
display
0320
Temperature
Indication
Scale
0330
Daylight
Savings
1--daylight
savings
is on (factory
setting).
0--daylight
savings
is off.
0340
0350
0--no
remote
temperature
sensor
l--outdoor
temperature
sensor
for displayonly.
2--outdoor
temperature
sensor
for control.
Outdoor
sensor
used for Heat Pump
Lockout
settings.
(See Heat
Pump
Temperature
Lockout
section
for more details.)
3--indoor
temperature
sensor
0--no compressor lockout.
Remote
Temperature
Sensor
(Outdoor
or
Indoor)
Heat Pump
Compressor
Set to 0 in areas
that do
not follow daylight
savings.
Defaults
and Options
depend
on System
Type
selection.
indoor
Temperature
Sensor
uses an averaging
network
and does
not
include
on-board
sensor.
Default
depends
on other
Lockout
or (Balance
Point)
15°F(-9.5°C)
20°F (-6.5°C)
25°F (-4°C)
30°F (-1 °C)
35°F (1.5°C)
40°F (4.5°C)
45°F (7°C)
selections.
Shown
if
Outdoor
Temperature
for
control
is selected.
(See
Advanced
Features
section
for more
information.)
17
68-0280