SYSTEM INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow the
instructions can damage the product or cause a haz-
ardous condition.
2. Check the ratings given in the instructions to make
sure the product is suitable for your application.
3. Installer must be a trained, experienced service
technician.
4. After completing installation, use these instructions
to verify the product operation.
Finding Your Password (Date Code)
You will need the thermostat password to:
• Make changes to Installer Setup
• Perform an Installer Test
• Reset Thermostat to Factory Default Settings
The password (date code) is located on the back of the
thermostat (see Fig. 2)
VISIONPRO® 8000 SMART THERMOSTAT
Fig. 2. Finding thermostat password.
You can also find the password (date code) by pressing
MENU, selecting Dealer Information and then scrolling
down to see the Date Code.
5
RoHs Compliant
Conformité RoHs
Assembled in Mexico
Assemblé au Mexique
1
M37810A
Password
(Date Code)
33-00096—05

Advertisement

loading

Summary of Contents for Honeywell VISIONPRO 8000

  • Page 1 VISIONPRO® 8000 SMART THERMOSTAT SYSTEM INSTALLATION When Installing this Product... 1. Read these instructions carefully. Failure to follow the instructions can damage the product or cause a haz- ardous condition. 2. Check the ratings given in the instructions to make sure the product is suitable for your application.
  • Page 2: Installation

    VISIONPRO® 8000 SMART THERMOSTAT INSTALLATION Selecting Discharge Air Temperature Sensor Mounting Location 1. Install the Discharge Air Temperature Sensor on the duct in a location where the air is mixed well. See Model Numbering TH8321 Fig. 3–7. Stages 3H/2C HP 2H/2C CONV ...
  • Page 3: Installing Discharge Air Temperature Sensor

    VISIONPRO® 8000 SMART THERMOSTAT ALTERNATE MOUNTING LOCATION FOR DISCHARGE SENSOR. MOUNT DISCHARGE BYPASS SENSOR HERE HUMIDIFIER VENTILATOR DEHUMIDIFIER DEHUMIDIFIER MOUNT DISCHARGE SENSOR HERE ABOVE CENTER HEAT OF A-COIL EXCHANGER UPSTREAM OF DEHUMIDIFIER HEAT EXCHANGER BLOWER M35772 BLOWER Fig. 7. M35770 Installing Discharge Air Fig.
  • Page 4: Selecting Thermostat Location

    VISIONPRO® 8000 SMART THERMOSTAT Selecting Thermostat Location 2. Position and level the wallplate (for appearance only). 3. Use a pencil to mark the mounting holes. Install the thermostat about 5 ft. (1.5m) above the floor in an 4. Remove the wallplate from the wall and, if drywall, area with good air circulation at average temperature.
  • Page 5: Finding Your Password (Date Code) To Access Installer Options

    VISIONPRO® 8000 SMART THERMOSTAT Finding Your Password (Date Code) CONVENTIONAL to Access Installer Options You need a password (Date Code) to access Installer Options. Installer Options allow you to: • Make changes to the Installer Setup. • Perform an Installer Test. •...
  • Page 6: Make Changes To Installer Setup

    VISIONPRO® 8000 SMART THERMOSTAT Thermostat Password (Date Code) Table 1. Installer Options. Menu Item Description Installer Setup Select INSTALLER SETUP to set system settings one by one. Installer Test Select INSTALLER TEST to quickly determine if the heat, cool, fan and RoHs Compliant Conformité...