Installer Setup Menu - Honeywell VisionPRO 8000 Owner's Manual

Visionpro 8000 series touchscreen programmable thermostat
Hide thumbs Also See for VisionPRO 8000:
Table of Contents

Advertisement

VisionPRO
TM 8000
Touchscreen
Programmable
Thermostat
Table 3. Installer
Setup
Menu.
Installer
Setup
Number
Installer
Setup
Name
Notes
0120
Date (Year Upper)
2001
- 2178
available
0130
Date (Year Lower)
2001
- 2178
available
0140
Date (Month)
0150
Date (Day)
0160
Schedule
Options
0170
System
Type Selection
Settings
Select
first two digits
of current
calendar
year (2005,
etc)
Select
last two digits of current
calendar
year (05 for year
2005, etc)
Select
number
that represents
current
calendar
month
Select
number
that represents
current
calendar
date
0--nonprogrammable
4--7-day
programmable
1--1
heattl
cool conventional
(factory
setting)
2--single-stage
heat pump
(no auxiliary
heat)
3--heat
only conventional
(no fan) Also
for 750mV.
4--heat
only conventional
(with fan)
5--heat
only (power
to open
and power
to close
zone
valves
or normally-open
zone valves)
6--cool
only conventional
7--2
heat/1
cool heat pump
(with auxiliary
heat)
8--2
heatt2
cool multistage
conventional
9--2
heattl
cool multistage
conventional
10--1
heat/2
cool multistage
conventional
11--2
heatt2cool
heat pump
(no auxiliary
heat)
12--3
heat/2cool
heat pump
(with auxiliary
heat)
0--gas
or oil furnace
equipment
controls
fan in heating
(factory
setting)
l--electric
furnace--thermostat
controls
fan in heating
Available
options
and
defaults
vary by
thermostat.
System
selection
automatically
modifies
some
default
Cycles
per hour (cph) for
1st Stage Compressor
Cycles per hour (cph) for
2nd Stage Compressor
Cycles per hour (cph) for
1st Stage Conventional
Heat
settings
and/or
hides
other
installer
Setup
options.
0180
Fan Control
in Heating
Only shown
if
conventional
system
is
selected.
If heat pump
is
chosen,
fan defaults
to
electric.
0190
Changeover
Valve--O/B
Only shown
if heat pump
Terminal
Energized
in
system
is chosen.
Heating
or Cooling
(Heat Pumps
Only)
0200
Backup
Heat Source
Only shown
if 2 heat/
(Auxiliary
Heat)
1 cool or 3 heat/2
cool
heat pump
is chosen
0210
External
Fuel Fossil
Only shown
if fossil fuel is
Fuel Kit
chosen
as backup
heat
source.
0220
0230
Only shown
if two stages
of cool are selected.
0240
Not shown
if system
selection
is heat
pump.
0--changeover
valve--O/B
terminal
is energized
in
cooling
(factory
setting)
1--changeover
valve--OIB
terminal
is energized
in
heating
0--heat
pump
backup
heat source
is electric
(factory
setting)
l--heat
pump
backup
heat source
is fossil fuel
0--no
external
fossil fuel kit is controlling
heat pump
backup
heat. This thermostat
controls
the dual fuel. Must
install outdoor
sensor
and set Installer
Setup
Number
0340 to number
2.
1--external
fossil fuel kit is controlling
heat pump
backup
heat
3--cph
recommended
for compressors
(factory
setting)
1, 2, 4, 5, 6--other
cycle
rate settings
3--cph
recommended
for compressors
(factory
setting)
1, 2, 4, 5, 6--other
cycle
rate settings
1--
1 cph used for steam
and gravity
3--3
cph used for hot water
system
and high efficiency
(90% or better) furnaces
5--5
cph used for standard
fossil fuel forced
air (less than
80% efficient)
systems
(factory
setting)
9--9
cph used for electric
furnaces
2, 4, 6, 7, 8, 10, 11, 12--other
cycle rate settings
1--1
cph used for steam
and gravity
3--3
cph for hot water systems
and high efficiency
(90%
or better)
furnaces
5--5
cph for standard
fossil fuel forced
air (less than 90%
efficient)
systems
(factory
setting)
9--9
cph used for electric
furnaces
or electric
auxiliary
heat for heat
pump systems
2, 4, 6, 7, 8, 10, 11, 12--other
cycle rate settings
Cycles per hour (cph) for
2nd Stage
Heat (Aux
Heat for 2H/1C
Heat
Pumps)
Selection
in this stage
changes
default
cph for
2nd stage heat.
Only shown
if two stages
of heat are selected.
0250
68-0280
16