Configuring Individual Ports

To configure an individual port, click on the port in the table to bring up the Port Configuration window.
From the Port Configuration window, you can edit the port's configuration, view port information, edit CPE
options, and modify alarm thresholds.
Edit Configuration
Click on Edit Configuration in the menu tree of the Port Configuration window. Circuit ID, Desired State,
Test Mode and Test Pattern are configurable.
1. Enter the Circuit ID (optional) in the text field.
2. Select an option from the Desired State drop-down menu:
• Deactivated(0)—Select this option when the port is not currently connected to a remote CPE modem.
• Activated(1)—Select this option to connect the port to a remote CPE modem for current active use.
• Reset(2)—Select this option to reset the iDSL port.
3. Select an option from the Test Mode drop-down menu:
• localLoop(1)—The T-DAC's iDSL port will operate in local loopback mode. Data transmitted through
the 3196RC to the iDSL port is looped back to the transmitting port.
• remoteLoop(2)—For a Patton CPE iDSL modem that provides a serial port (such as the model 1082),
and that is remotely connected to this iDSL port, remoteLoop(2) changes the operating mode of the serial
port. The 3196RC will cause the serial port on the remote CPE to operate in loopback mode.
• lineLoop(3)—The 3196RC's iDSL port will operate in line loopback mode. For the CPE remotely con-
nected to this port, you can use lineLoop(3) mode to test the iDSL link from the CPE to the 3196RC and
back to the CPE.
• none(0)— The default value for Test Mode.
Configuring iDSL Ports
Figure 96. 3196RC Edit iDSL Configuration