Attaching The Rear Or Front Rack Mount Brackets; Securing The Inner Slide Rails To The Switch - HP StorageWorks 2/16 - SAN Switch Installation Manual

San switch 2/16 version 3.0.x installation guide
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Installing the SAN Switch 2/16
3. Tighten the screws and torque to 15-inch pounds.
Figure 4: Securing the inner slide rails to the switch
4. Repeat steps 1 and 2 to attach the second inner slide rail to the switch. Make

Attaching the Rear or Front Rack Mount Brackets

The Rack Mount Kit supplied with the switch contains two rear rack mount
brackets and two front rack mount brackets. Install these rack mount brackets to
prevent the switch from accidentally sliding out of the rack, as follows.
Note:
the back of the HP 9000 Series Rack. (For example, the switch should face the aisle
where exhaust air is released. Air intake and exhaust for all components in the rack
should flow in the same direction.)
32
sure to orient the second inner slide rail in the same way you positioned the
first (based on 1a or 1b above).
HP recommends installing the switch so that the port side of the switch slides out
SHR-2477A
hp StorageWorks SAN Switch 2/16 Installation Guide