Power Supply Specifications

Table 7
capable of functioning worldwide without using voltage jumpers or switches. It
meets IEC 61000-4-5 surge voltage requirements. The power supply has its own
built-in fan for cooling, pushing the air towards the front of the switch.
Table 7: Power Supply Specifications
Outlet
Total power available from each
power supply
Max. switch power
Input voltage
Input line frequency
Harmonic distortion
BTU rating
Inrush current
Input line protection
.
hp StorageWorks SAN Switch 2/16 Installation Guide
lists power supply specifications. The power supply is universal and
Specification
Value
Correctly wired and earth-grounded
126 Watts, with fans operating
90 - 102 Watts (depending on SFP
media vendor)
100 - 240 VAC
47 - 63 Hz
Active power factor correction per
IEC1000-3-2
170 Watts x 3.412 BTU/Hr/Watts =
580 BTU/hr
10 Amps Peak, > 300 usec - hot/cold
start
Fused in both hot & neutral lines
Technical Specifications