Isl Trunking; Sfps; Power Supply Side; Power Supply Side - HP StorageWorks 2/16 - SAN Switch Installation Manual

San switch 2/16 version 3.0.x installation guide
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

ISL Trunking

ISL trunking is a Fabric OS feature that enables distribution of traffic over the
combined bandwidth of up to four ISLs between two directly adjacent switches,
while preserving in-order delivery. For specific information about ISL trunking,
refer to the hp StorageWorks trunking version 3.0.x/V4.0.x user guide.

SFPs

The ports connect to SFP media. SFPs are universal and self-configuring.

Power Supply Side

Figure 2
power supplies, and switch status LED. Each power supply also integrates a
separate status LED. The power supplies, fan trays, and motherboard are all Field
Replaceable Units (FRUs).
1
2
3
Figure 2: Power supply side

Field-Replaceable Units

The power supplies, fan trays, and motherboard can all be replaced in the field,
without the use of special tools. The switch continues operating during the
replacement of a fan tray or power supply, if they are replaced one at a time. The
switch must be turned off during replacement of the motherboard. To simplify
replacement, the switch has a minimum of internal cables and no jumpers or
hardware settings. Replacement instructions are provided with all replacement
units ordered.
hp StorageWorks SAN Switch 2/16 Installation Guide
shows the rear panel of the switch. The rear panel houses the fan trays,
1
7
6
Power supply LED
Port readiness LED
Power supply
2
5
4
Fan tray assembly (inside chassis)
4
Spring latch (2)
5
Power switch
6
Power supply
7
Overview
3
SHR-2475A
21

Advertisement

Table of Contents
loading