Table 16 Logical path troubleshooting (continued)
Path status
Logical Blockade
Program Error
<blank>

Troubleshooting suspended pairs

Troubleshooting information for user-suspended and system-suspended pairs is provided in the
following two tables.
Hardware failures affecting the cache memory and the shared memory of the primary or secondary
system may also cause the pairs to be suspended.
Table 17 Suspended pair troubleshooting
Suspend type
PSUE, by
RCU
PSUE, S-VOL
Failure
Description
A failure occurs at a
primary system port.
A failure occurs at a
secondary system port.
A failure occurs in the path
relay equipment.
The connection cable is
physically broken.
Program error is detected.
This path was not
established.
Applies to
Description
P-VOL
The primary storage system suspended a
pair because the primary storage system
detected an error condition at the
secondary storage system. The suspend
type for the S-VOL is by MCU.
P-VOL
The primary storage system detected an
error during communication with the
secondary storage system or detected an
I/O error during update copy. In this
case, the suspend type for the S-VOL is
usually by MCU.
Corrective action
Repair the port status on the primary system.
Repair the port status on the secondary system. After that, delete the
path then add the path and the secondary system back again.
Repair the path relay equipment. After that, delete the path then add
the path and the secondary system back.
Replace the broken cable. After that, delete the path by using the
Delete Path or Delete DKC command, and then add the path and the
secondary system again by using the Add Path or Add DKC command.
Delete the path by using the Delete Path or Delete DKC command,
and then add the path and the secondary system again by using the
Add Path or Add DKC command.
Delete the failed path. You may need to change the minimum paths
setting or delete the secondary system in order to delete the path.
After deletion finishes, add the path and the secondary system by
using the Add Path or Add DKC command.
Corrective action
Clear the error condition at the secondary
storage system or S-VOL. If you need to
access the S-VOL, release the pair from the
primary storage system. If data in the S-VOL
has been changed, release the pair from the
primary storage system and then re create
the pair by using the Paircreate dialog box.
If data in the S-VOL has not been changed,
restore the pair from the primary storage
system.
Check the path status on the DKC Status
dialog box (see
paths " (page
conditions at the secondary storage system
and the S-VOL. If you need to access the
S-VOL, release the pair from the secondary
storage system. If data in the S-VOL has
been changed, release the pair from the
primary storage system and then re create
the pair by using the Paircreate dialog box.
If data in the S-VOL has not been changed,
restore the pair from the primary storage
system.
"Troubleshooting logical
105)). Clear any error
Troubleshooting suspended pairs 107