Table 19 RAID Manager error codes for Continuous Access Journal (continued)
Error code (SSB1)
120 Troubleshooting
Error code (SSB2)
Error content
EB28
A request to create or resynchronize a pair in the system that consists of
multiple primary and secondary systems was rejected because the Cont
Access Journal 3DC & 4x4 Open MF program product was not installed
in the secondary system.
EB29
A request to configure the system that consists of multiple primary and
secondary systems was rejected because the delta resync settings are
configured to the primary and secondary systems.
EB2F
A request of Cnt Ac-J Paircreate for delta resync operation was rejected
because the specified Cnt Ac-J pair was used in the system that consists of
multiple primary and secondary systems.
EB30
A request of Cnt Ac-J pair status transition was rejected because the specified
mirror ID was invalid.
EB45
The specified Cnt Ac-J pair cannot execute the takeover because the
specified Cnt Ac-J pair belongs to the journal that dedicated Cnt Ac-J and
Continuous Access Synchronous combination (2DC configuration).
EB48
A delta resync pair cannot be created due to one of the following reasons.
P-VOL of the Cnt Ac-J pair is different from P-VOL of the Continuous
Access Synchronous pair.
The serial number of the primary system that is recognized by P-VOL
and S-VOL is different.
EB49
A request of Cnt Ac-J Paircreate (journal suspend mode) was rejected
because the secondary system did not support the delta resync function.
EB4C
A pair cannot be created because the restore journal was not registered.
EB4D
A pair cannot be created because the master journal was not registered.
EB50
A request of Cnt Ac-J Paircreate was rejected because the specified S-VOL
was not mounted.
EB51
The Cnt Ac-J pair cannot be created because PIN data existed in the
specified S-VOL.
EB52
The Cnt Ac-J pair cannot be created because the specified S-VOL cannot
be accessed.
EB53
The Cnt Ac-J pair cannot be created because the specified S-VOL is blocked.
EB57
The command was rejected because the specified S-VOL was online from
the host.
EB58
The command was rejected because the specified journal volume or S-VOL
was reserved or being used in the storage system. Please check the status
of the volume.
EB59
The command was rejected because the specified S-VOL was being migrated
by Auto LUN. Please check the status of the volume.
EB5B
The Cnt Ac-J pair cannot be created because the access attribute was set
to the specified P-VOL or S-VOL by the Data Retention.
EB5C
Cnt Ac-J pair cannot be resynchronized because an internal logical error