To identify the error code in the log file, open the RAID Manager log file, and find the error code.
Example: 1 1:06:03-37897- 1 0413- SSB = 0xb9a0,2089
Error codes appear on the right of the equal symbol (=). The alphanumeric characters on the left
of the comma (,) indicates SSB1 (for example, B901), and on the right of the comma (,) indicates
SSB2 (for example, 4A96).
The meaning of each error code is shown below.
Table 19 RAID Manager error codes for Continuous Access Journal
Error code (SSB1)
B901/B9E0/B9E1/
B9E2/B9E4/D004
1 10
Troubleshooting
Error code (SSB2)
Error content
3703
A request of Cnt Ac-J Pairresync (suspend transition mode) was rejected
because the PIN data was existed in the journal volume.
3704
A request of Cnt Ac-J Paircreate was rejected because the emulation types
of the specified master journal and of the restore journal were different.
3705
A request of Cnt Ac-J Paircreate (journal suspend mode) or Cnt Ac-J
Pairresync (journal resync mode) was rejected because the version of the
secondary system did not support the corresponding command.
3706
A request of Cnt Ac-J Paircreate (journal suspend mode) was rejected
because the specified P-VOL was used as the S-VOL of Continuous Access
Synchronous, and the pair status was not PAIR.
3707
A request of Cnt Ac-J Pairresync (journal resync mode) was rejected because
of the one of following reasons.
The specified P-VOL was the P-VOL of Continuous Access Synchronous,
and the Cnt Ac-J pair status was not PAIR.
The specified P-VOL was the S-VOL of Continuous Access Synchronous,
and the Cnt Ac-J pair status was not SSWS.
3708
The Cnt Ac-J pair cannot be created because the specified P-VOL was being
shredded.
3709
A request of Cnt Ac-J Paircreate (journal suspend mode) or Cnt Ac-J
Pairresync (journal resync mode) was rejected because the specifying of
the restore journal was incorrect.
370B
The Cnt Ac-J pair cannot be resynchronized (DELTAJNL parameter
specifying), because the specified P-VOL is not in the either of HOLD or
HOLDTRNS status. Or, the Cnt Ac-J pair cannot be resynchronized (ALLJNL
parameter specifying), because the specified P-VOL is not in the either of
HOLD, HOLDTRANS, or NODELTA status.
370C
A request of Cnt Ac-J Paircreate (journal suspend mode) or Cnt Ac-J
Pairresync (journal resync mode) was rejected because the status of the
specified master journal or restore journal could not be transited, or the
status transition was in progress.
371C
A request by Cnt Ac-J Paircreate or Cnt Ac-J Pairresync was rejected because
the Cnt Ac-J pair was in a status other than Suspending or was not used in
the 2DC configuration.
371D
The journal was registered when 2DC Cascade was set to Enable in the Edit
Journal Volume dialog box.
In the 2DC Cascade configuration, the Cnt Ac-J pair cannot be created
when the Continuous Access Synchronous is in existence. Also, the 3DC
multitarget configuration cannot be created.