HP StorageWorks P9000 User Manual page 119

Continuous access journal user guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 19 RAID Manager error codes for Continuous Access Journal (continued)
Error code (SSB1)
Error code (SSB2)
EA95
EAA2
EAA3
EAA5
EAA6
EAD0
EAE5
EAE7
EAEB
EAF6
EB24
EB25
Error content
A request of Cnt Ac-J Paircreate was rejected because the volume specified
for the primary volume was being initialized by Business Copy.
A request of Cnt Ac-J Paircreate was rejected because the desired capacity
exceeded the charging capacity of the primary system's Cnt Ac-J. Check
the license capacity as well as the related program product.
A request of Cnt Ac-J Paircreate was rejected because the desired capacity
exceeded the charging capacity of the secondary system's Continuous
Access Synchronous. Check the License capacity as well as the related
Program product.
A request of Cnt Ac-J Paircreate was rejected because the desired capacity
exceeded the charging capacity of the secondary system's Cnt Ac-J. Check
the license capacity as well as the related program product.
A request of Cnt Ac-J Paircreate was rejected because the desired capacity
exceeded the charging capacity of the primary system's Continuous Access
Synchronous. Check the license capacity as well as the related program
product.
A request of Cnt Ac-J Paircreate (journal suspend mode) was rejected
because the delta resync function was unsupported.
A request of Cnt Ac-J Paircreate was rejected because the specified P-VOL
or S-VOL is in the process of having the capacity changed by Thin
Provisioning.
The Cnt Ac-J pair cannot be deleted because the specified Cnt Ac-J volume
is used as the Continuous Access Synchronous pair and is working in the
journal that was registered when the 2DC Cascade was set to Enable in the
Edit Journal Volume dialog box.
A request of Cnt Ac-J Paircreate was rejected because the discarding process
of zero data in the specified P-VOL or S-VOL is in progress by Thin
Provisioning.
A request of Cnt Ac-J Paircreate (journal suspend mode) or Cnt Ac-J
Pairresync (journal resync mode) was rejected because the pair was in the
state that was unavailable to transit.
The Cnt Ac-J pair for the delta resync operation cannot be created because
the specified Cnt Ac-J S-VOL is in either one of the following statuses:
The volume cannot be used as the Cnt Ac-J volume for the delta resync
operation.
The status of the Cnt Ac-J pair is other than PAIR.
The Cnt Ac-J pair for delta resync operation cannot be created because the
specified Cnt Ac-J S-VOL is in either one of the following statuses:
The volume cannot be used as the Cnt Ac-J volume for the delta resync
operation.
The status of the Cnt Ac-J pair is the status other than PAIR or SUSPEND.
Troubleshooting using RAID Manager
1 19

Advertisement

Table of Contents
loading

Table of Contents