Table 19 RAID Manager error codes for Continuous Access Journal (continued)
Error code (SSB1)
122 Troubleshooting
Error code (SSB2)
Error content
EB80
The command was rejected because the specified volume was the V-VOL
or the pool-VOL. Please check the status of the volume.
EB87
A request of Cnt Ac-J Paircreate was rejected because the path from the
secondary system to the primary system was not set, or the S-VOL was in
the SMPL status.
EB88
The Cnt Ac-J pair was not created because of one of the following:
The specified S-VOL was being used as a Business Copy S-VOL.
The specified S-VOL was Not Ready, which means that the hard disk
drive cannot be used.
EB89
A request of Cnt Ac-J Paircreate was rejected because the emulation types
of the specified P-VOL and S-VOL were not the same.
EB8A
A request of Cnt Ac-J Paircreate was rejected because the emulation types
of the specified master journal and the restore journal were not the same.
EB8E
The Cnt Ac-J pair cannot be created because the LUSE configuration of the
P-VOL is different from the LUSE configuration of S-VOL.
EB94
A request of Cnt Ac-J pair status transition was rejected because the specified
pair could not transit the status.
EBA0
A request of Cnt Ac-J pair status transition was rejected because the specified
S-VOL was not mounted on the secondary system.
EBA7
A request of Cnt Ac-J Paircreate was rejected because the volume specified
for the secondary volume was in either one of the following status.
Increasing the capacity by Thin Provisioning.
Releasing the page of Thin Provisioning.
Being initialized by Business Copy.
EBCA
A request of Cnt Ac-J Pairresync (journal resync mode) was rejected because
the journal restore operation is in progress in the Cnt Ac-J pair through
another mirror ID.
If the Cnt Ac-J pair with another mirror ID is in Suspending status, re-issue
the request when the pair status is changed to the Suspend status.
If the Cnt Ac-J pair with another mirror ID is in the PAIR status, reissue
the request after awhile.
EBAF
The Cnt Ac-J pair cannot be created because the license capacity of the
Data Retention in the secondary system exceeds the setting value. Please
check the license capacity setting for Data Retention in the secondary system.
EBC6
The Cnt Ac-J pair for delta resync operation cannot be created because the
specified Cnt Ac-J S-VOL was used by either Business Copy or Compatible
FlashCopy.
EBCE
The Cnt Ac-J pair cannot be resynchronized (DELTAJNL parameter specified),
because nonupdated differential data exists in the specified S-VOL.

Advertisement