4023-001
Finisher Upper Entrance Service Check
FRU
1
• Upper
Entrance
Switching
Solenoid
(SL1)
• Upper
Switching
Plate
• Finisher
Main Board
PWB-A
Action
Paper entrance switch mechanism fails to operate
correctly.
• Check the upper entrance switching solenoid
SL1.
• Check the path of the paper through the upper
entrance switching plate.
• If problem persists, replace the finisher main
board PWB-A.
Diagnostic Information