Cleaning and replacing the air filter

The air filter unit of this projector consists of a filter cover, two kinds of filters, and
a filter frame. The new double large filters system is expected to function longer.
However, please check and clean it periodically to keep ventilation needed for
normal operation of the projector.
When the indicators or a message prompts you to clean the air filter, comply with
it as soon as possible. Replace the filters when they are damaged or too soiled.
To prepare new filters, make contact with your dealer and tell the following type
number.
Type number : MU05611
When you replace the lamp, please replace the air filter. An air filter of specified
type will come together with a replacement lamp for this projector.
1.
Turn the projector off, and unplug the power cord.
Allow the projector to sufficiently cool down.
2.
Use a vacuum cleaner on and around the filter cover.
3.
Pull the filter cover knobs while lifting it, to take the
filter unit off.
4.
Use a vacuum cleaner for the filter vent of the
projector and both sides of the filter unit.
If the filters are damaged or too soiled, replace them
according to the following procedure number 5 to 7.
Otherwise, please jump to the procedure number 8.
5.
Pull the filter frame's knob up while holding the filter
cover to remove the filter frame, then take the filters
out.
6.
Set new filters where former filters were. Put the larger
meshed filter into a filter cover first. Then put the finer
meshed filter on the larger meshed one.
7.
Put the filter frame back where it was.
8.
Put the filter unit back into the projector.
(continued on next page)
Maintenance
Filter cover
Filter cover knobs
Filter unit
Filter frame
Filter (finer meshed)
Filter (larger meshed)
Filter cover
69