2. At the ILOM -> prompt, type:
-> set /SYS keyswitch_state=diag
The system is set to run full POST diagnostics on system reset.
3. To return to your normal diagnostic settings after running POST, type:
-> set /SYS keyswitch_state=normal
Related Information
"Clearing Faults" on page 33
■
"Bypassing Minor Faults" on page 31
■
"Managing Devices" on page 34
■
"Locate the System" on page 30
■
▼ Locate the System
1. Log in to ILOM.
See
2. To easily find your system in a data center or server room, use the Locator LED
as described below.
■
-> set /SYS/LOCATE value=Fast_Blink
■
-> set /SYS/LOCATE value=off
■
-> show /SYS/LOCATE
For more information on LEDs, see your server's service manual.
Related Information
"Configure a Device Manually" on page 35
■
"Clear Component Fault Messages" on page 34
■
30
SPARC Enterprise T5440 Server Administration Guide • July 2009
"Log In to ILOM" on page
To turn on the Locator LED, from the ILOM -> prompt, type:
To turn off the Locator LED, from the ILOM -> prompt, type:
To display the state of the locator LED, from the ILOM -> prompt, type:
28.