Hot-Plug A Mirrored Disk - Fujitsu SPARC Enterprise T5440 Server Administration Manual

Hide thumbs Also See for SPARC Enterprise T5440 Server:
Table of Contents

Advertisement

Related Information
"Creating RAID Volumes" on page 14

▼ Hot-Plug a Mirrored Disk

1. Verify which hard drive corresponds with which logical device name and
physical device name.
See
"Disk Slot Numbers" on page
2. To confirm a failed disk, type:
# raidctl
If the Disk Status is FAILED, then the drive can be removed and a new drive
inserted. Upon insertion, the new disk should be OK and the volume should be
RESYNCING.
For example:
# raidctl
RAID
Volume
-----------------------------------------------------------------
c0t1d0
This example indicated that the disk mirror has degraded due to a failure in disk
c0t2d0.
3. Remove the hard drive as described in your server's service manual.
There is no need to issue a software command to bring the drive offline when the
drive has failed.
4. Install a new hard drive as described in your server's service manual.
The RAID utility automatically restores the data to the disk.
20.
Volume
RAID
Type
Status
IM
DEGRADED
RAID
RAID
Disk
Status
c0t1d0
OK
c0t2d0
FAILED
Manage Disk Volumes
23

Advertisement

Table of Contents
loading

Table of Contents