Vibration:
21V Power Supply Board Performance Specifications
Input Voltage (Vin):
Input Current (Iin):
Output Voltage (Vout):
Output Current (Iout):
Ripple/Noise:
Efficiency:
Fuses:

4.7 ENVIRONMENTAL SPECIFICATIONS

Temperature:
Relative Humidity:
Vibration:
RFI Susceptibility:
ESD:

4.8 DIMENSIONS

4-Slot Base Chassis:
8-Slot Base Chassis:
NEMA 3X Enclosure
4-10 / Specifications
1g for 10Hz to 500Hz per PMC-31-1 (without damage or
impairment)
10.8V to 16V (dc)
100mA (Typ. @ 12V & 50mA load)
140mA (Max. over Temp. Range @ 50mA load)
21.4Vdc ±0.8V
50mA (Max.)
20mV (Max. P-to-P)
88% (Typ.)
F1 = 500mA (Slow Blow): Protects host power source from
F2 = 350mA(Fast Blow): Protects 21V Pwr. Supply Bd.
Operating:
-40 to +158 °F (-40 to +70 °C)
Storage:
-40 to +158 °F (-40 to +70 °C)
0-95% Non-condensing
2g for 10 - 150 Hz
1g for 150 - 2000 Hz
In conformity with the following standards:
IEC 1000-4-3 (Level 2): 3V/meter - 80MHz to 1000MHz
Field connected circuits meet the requirements of IEC
1000-4-2 for ESD withstand capability up to 4KV
see Figure 4-3
see Figure 4-4
see Figure 4-5
failures within the 21V Pwr.
Supply Bd.
circuitry from short circuits on
an output.
CI-ControlWave EFM

Advertisement