Kyocera KM-C2230 User Manual page 344

Km-c2230 users manual
Hide thumbs Also See for KM-C2230:
Table of Contents

Advertisement

10.10 Specifying Expert User Mode Functions
8
Press the [Start] key.
The test pattern is
printed on 11 × 17-size
paper.
9
Check that the top margin of the
test pattern is between 4.5 mm.
and 5.5 mm. If the top margin is
within the specified range, skip to
step 14.
10
If the top margin is less than 4.5
mm, touch
desired positive adjustment
(between +0.1 mm and +3.0
mm).
11
If the top margin is more than 5.5
mm, touch
desired negative adjustment (between -0.1 mm and -3.0 mm).
12
Press the [Start] key.
The adjusted test pattern is printed on 11 × 17-size paper.
13
Check the print result.
Make sure that the top margin is adjusted to between 4.5 mm and 5.5 mm.
If more adjustment is necessary, return to step 10 and repeat the adjustment
procedure.
14
Touch [Enter].
15
Touch [Exit] in the next three screens that appear.
The Basic screen appears again.
to specify the
to specify the
a
a: 5.0 mm ± 0.5 mm
10
10-81