24 electrolux
PROBLEM
• The display shows „ 12.00 ".

Technical data

Heating element ratings
Bottom oven element
Top heating element
Full oven (Top+Bottom+ Fan)
Grill
Thermal grill
Full grill
Fan Cooking heating
Oven light
Hot air fan motor
Cooling fan motor
Turnspit motor
Pyro

Installation

Instructions for the Installer
Important!
Installation and connection must be
done in compliance with the regulations
in force. Any interventions must be
carried out when the appliance is
switched off. Only qualified service
engineers may repair the appliance
The manufacturing company disclaims
any liability if the safety measures are
not observed.
Connecting to the electrical supply
Before connecting to the electrical supply,
please make sure:
– The fuse and the domestic electrical in-
stallation must be designed for the max.
load of the appliance (see rating plate).
– The domestic electrical installation must
be equipped with a proper earth connec-
tion in accordance with the regulations in
force.
– The socket or the multi-pole off switch
must be easy to access after the appliance
has been installed.
This appliance is supplied with a connection
cable incorporating a standard plug, suitable
• Set the time of day (see chapter "Setting the
clock").
Total connection rating
1000 W
Operating voltage (50 Hz)
800 W
Dimensions of the recess
1825 W
Height under top
1650 W
Height under in column
1650 W
Width
2450 W
Depth
1825 W
Oven levels
40 W
25 W
Height
25 W
Width
4 W
Depth
2475 W
Oven capacity
for the total electric load shown on the rating
plate. The plug is to be inserted into a suitable
wall socket.
The following types of mains cable are suit-
able, taking the necessary rated cross sec-
tion into account:
H07RN-F, H05RN-F, H05RR-F, H05VVF,
H05V2V2-F (T90), H05BB-F.
If the appliance is connected without a plug,
or if the plug is not accessible, a multipole off
switch (e.g. fuses, circuit breaker) with a min-
imum gap of 3 mm between the contacts
must be installed between the appliance and
mains cable. The switch must not interrupt
the earth wire at any point. The yellow-green
earth wire should be 2-3 cm longer than all
other cables.
The connection cable must always be laid
out so that at no point does it reach 50°C
(over room temperature).
After the connection has been carried out,
the heating elements must be tested by be-
ing operated for about 3 minutes.
Terminal block
The oven is fitted with an easily accessible
terminal block which is designed to operate
with a single phase power supply of 230 V.
SOLUTION
2700 W
593 mm
580 mm
560 mm
550 mm
335 mm
395 mm
400 mm
53 l
230 V